background image

5

Remote controller

How to set the batteries and the current
time

1

Remove the front lid and insert batteries.
Then reattach the front lid.

Insert the minus pole of the batteries first.
Check if the polarity of the batteries is correct.

2

Press the RESET button.

If the RESET button is not pressed, the remote con-
troller may not operate correctly.

3

Press the CLOCK set button.

4

Press the 

HR.

 and 

MIN.

 buttons (TIME SET

buttons) to set the current time.

Each time the 

HR.

 button is pressed, the set time

increases by 1 hour, and each time the 

MIN.

 button

is pressed, the set time increases by 1 minute.

5

Press the CLOCK set button again and close
the front lid.

Press using a
thin stick.

Press using a
thin stick.

Insert the minus pole
of the batteries first.

Remote controller
holder

1

Press the EMERGENCY OPERATION switch.

Each time the EMERGENCY OPERATION switch is
pressed, the unit will operate in order of EMER-
GENCY COOL MODE, EMERGENCY HEAT MODE
and STOP MODE.
However, when the EMERGENCY OPERATION
switch is once pressed, the unit will operate in test
run for 30 minutes and then the operation mode
shifts to EMERGENCY MODE.

Details of EMERGENCY MODE are as shown be-
low. However, the temperature control does not
work for 30 minutes in test run and the unit is set
to continuous operation. The fan speed is set to
High in test run and shifts to Medium after 30 min-
utes.

Operation mode

COOL

HEAT

Set temperature

24°C

24°C

Fan speed

Medium

Medium

Horizontal vane

Auto

Auto

The operation mode is indicated by the Operation
Indicator lamp on the indoor unit as following fig-
ure.

Operation Indicator lamp

When the remote controller cannot be used (emergency operation)

When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation
can be done using the EMERGENCY OPERATION switch.

2

To stop the emergency operation, press the
EMERGENCY OPERATION switch once (in
case of EMERGENCY HEAT MODE) or twice
(in case of EMERGENCY COOL MODE).

Operation Indicator

Operation Indicator

Operation Indicator

EMERGENCY HEAT

EMERGENCY COOL

STOP

Handling of the remote controller

The range that the signal can reach is about 6 m when
the remote controller is pointed at the front of the in-
door unit.

When a button is pressed, one or two beeps will be
heard from the indoor unit. If no sound is heard, op-
erate again.

Use the remote controller carefully.
If it is dropped, thrown or it gets wet, the remote con-
troller may not operate.

When installing on a wall, etc.

Install the remote controller holder in a position where
the signal reception sound (beep) can be heard from
the indoor unit when the 

ON/OFF

 button is pressed.

How to install/remove the remote controller

Installing

:Insert the remote controller downward.

Removing :Pull it up.

Dry-cell batteries

 Reference for replacing batteries

Replace the batteries with new AAA alkaline batteries
in the following cases:

·

When the indoor unit does not respond to the remote
control signal.

·

When the display on the remote controller becomes
dim.

·

When a button of the remote controller is pressed, all
displays appear on the screen, and then disappear
immediately.

Do not use manganese batteries. The remote controller
could malfunction.

The service life of an alkaline battery is about 1 year.
However, a battery whose time limit is approaching
may be exhausted soon. The recommended usable
time limit is indicated (month/year) on the bottom of
the battery.

To prevent liquid leakage, take out all batteries when
the remote controller is not going to be used for a
long time.

 CAUTION:

If liquid from the batteries gets onto your skin or
clothes, wash it well with clean water.
If liquid from the batteries gets into your eyes, wash
them well with clean water and consult a doctor at
once.

Do not use rechargeable batteries.

Replace the 2 batteries with new ones of the same
type.

Dispose of exhausted batteries in the correct man-
ner.

PREPARATION BEFORE OPERATION

FAN

VANE

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

RESET CLOCK

I FEEL

COOL

DRY

AUTO

HEAT

Содержание MSZ-A09YV SERIES

Страница 1: ...r gli utenti Per utilizzare correttamente quest unità leggere questo libretto d istruzioni atten tamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË INSTRUÇÕES DE OPERAÇÃO Para os clientes Para utilizar esta unidade correctamente certifique se de que lê estas instruções de operação antes da utiliza...

Страница 2: ...ing the unit etc This may cause an injury etc if you fall down Do not pull the power supply cord The core wire of the power supply cord may be disconnected and this may cause a fire Do not charge or disassemble the batteries and do not throw them into a fire This may result in leakage fire or an explosion Do not operate the unit for a long time in high humidity e g leaving a door or window open In...

Страница 3: ...ade the insulation This may cause an electric shock Do not step or put anything on the indoor outdoor unit This may cause an injury etc if you or something falls down WARNING Consult your dealer for installation of the air conditioner CAUTION Do not install the unit where flammable gas could leak If gas leaks and collects around the unit it may cause an explosion Earth the unit Do not connect the ...

Страница 4: ... because the setting of the unit needs to be changed Auto restart function is When the indoor unit is controlled with the remote controller the operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to start operating in the same mode as the one set with the re...

Страница 5: ...nce in case of EMERGENCY HEAT MODE or twice in case of EMERGENCY COOL MODE Operation Indicator Operation Indicator Operation Indicator EMERGENCY HEAT EMERGENCY COOL STOP Handling of the remote controller The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the in door unit When a button is pressed one or two beeps will be heard from the indoor unit...

Страница 6: ...emperature is 2 C higher than the set temperature the set temperature may not be changed since the air conditioner is operating to reach the target set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than the set temperature the set temperature may not be chang...

Страница 7: ... in sequence I FEEL AUTO COOL DRY HEAT To stop operation Press the ON OFF button After the operation mode is set once the operation starts in the same mode as the one set previously from the next time by simply pressing the ON OFF button MANUAL OPERATION COOL DRY HEAT ON OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR MIN AMPM CLOCK C AMPM I FEEL COOL DRY AUTO HEAT RESET CLOCK ON OFF ...

Страница 8: ...c How to set the ON timer 1 Press the START button during operation Each time the button is pressed the ON timer mode alternates between ON and OFF 2 Set the time of the timer using the HR and MIN buttons Each time the HR button is pressed the set time in creases by 1 hour each time the MIN button is pressed the set time increases by 10 minutes To release the ON timer Press the START button How to...

Страница 9: ...d both ends of the front panel lift the panel up until its level and then pull it to wards you CAUTION Do not drop the front panel or pull it out forcibly The panel may be damaged Do not step onto an unstable bench when removing or installing the front panel This may cause an injury etc if you fall down 2 Wipe the front panel with a soft dry cloth or wash it with water After washing the panel wipe...

Страница 10: ...l ter with water If the dirt is noticeable wash the filter with a solu tion of mild detergent diluted in lukewarm water If hot water 50 C or more is used the filter may be deformed Open the front panel then remove replace the filter Catechin air filter Remove Install What is Catechin air filter The air filter is dyed with a natural material catechin that is contained in tea The catechin air filter...

Страница 11: ...rmed and the vanes may not work properly Put the vertical vanes back correctly to their original positions Otherwise condensed water may drip down from the indoor unit or the horizontal vanes could malfunction 6 Install the horizontal vanes Reverse the removal procedures Upper vane Lower vane Insert this end first Upper right Insert this end first Lower right After Cleaning Insert the power supply...

Страница 12: ... power failure as these models are equipped with an auto restart function the air conditioner should start operating again Refer to Descrip tion of AUTO RESTART FUNCTION on page 6 Question The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor...

Страница 13: ...akage or not when repairs are carried out The refrigerant charged in the air conditioner is safe Refrigerant normally does not leak however if refrigerant gas leaks indoors and comes into contact with the fire of a fan heater space heater stove etc harmful substances will be generated Electrical work Provide an exclusive circuit for the power supply of the air conditioner Be sure to observe the br...

Страница 14: ...310 JAPAN SG79Y280H01 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Страница 15: ......

Отзывы: