background image

12

BEFORE CONTACTING THE SERVICE REPRE-
SENTATIVE, CHECK THE FOLLOWING AGAIN

Question

The air conditioner cannot
be operated for about 3 min-
utes when restarted.

Cracking sound is heard.

The air from the indoor unit
smells strange.

The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to ro-
tate, it stops soon.

The sound of water flowing
is heard.

The sound as burbling is
heard.

The room cannot be cooled
sufficiently.

Mist is discharged from the
air outlet of the indoor unit.

Mechanical sound is heard
from the indoor unit.

Answer (not a malfunction)

• This protects the air conditioner according to in-

structions from the microprocessor. Please wait.

• This sound is generated by the expansion/con-

traction of the front panel, etc. due to change in
temperature.

• The air conditioner may suck in an odor adher-

ing to the wall, carpet, furniture, cloth, etc. and
blow it out with the air.

• When the outside temperature is low, the fan

may not operate to maintain sufficient cooling
capacity.

• This is the sound of refrigerant flowing inside

the air conditioner.

• This is the sound of condensed water flowing in

the heat exchanger.

• This is the sound of the heat exchanger defrost-

ing.

• This sound is heard when the outside air is ab-

sorbed from the drain hose in turning on the
range hood or the ventilation fan and that makes
water flowing in the drain hose spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside
wind is strong.

• When a ventilation fan or a gas cooker is used

in a room, the cooling load increases, resulting
in an insufficient cooling effect.

• When the outside air temperature is high, the

cooling effect may not be sufficient.

• The cool air from the air conditioner rapidly cools

moisture in the air inside the room, and it turns
into mist.

• This is the switching sound in turning on/off the

fan or the compressor.

WHEN YOU THINK THAT TROUBLE HAS OCCURRED

Question

The air conditioner cannot
be operated.

Both of the operation indi-
cator lamps on the indoor
unit are blinking.

The horizontal vane does
not move.

The room cannot be cooled
or heated sufficiently.

The air from the indoor unit
smells strange.

The display on the remote
controller does not appear
or it is dim. The indoor unit
does not respond to the re-
mote control signal.

When a power failure oc-
curs.

Check points

• Is the breaker turned on?
• Is the fuse blown?
• Is the ON timer set? (Page 8)

• Is the horizontal vane attached to the indoor unit

correctly? (Page 11)

• Are the horizontal vane and the vertical vane

attached to the indoor unit correctly? (Page 11)

• Is the fan guard deformed?

• Is the temperature setting correct? (Page 7)
• Is the filter clean? (Page 10)
• Is the fan of the indoor unit clean? (Page 11)
• Are there any obstacles blocking the air inlet or

outlet of the indoor or outdoor unit?

• Is a window or door open?

• Is the filter clean? (Page 10)
• Is the fan of the indoor unit clean? (Page 11)

• Are the batteries exhausted? (Page 5)
• Is the polarity (+, -) of the batteries correct?

(Page 5)

• Are any buttons on the remote controller of other

electric appliances being pressed?

• Does the air conditioner start operating again?

If the air conditioner had operated before the
power failure, as these models are equipped with
an auto restart function, the air conditioner
should start operating again. (Refer to Descrip-
tion of “AUTO RESTART FUNCTION” on page
6.)

Question

The air flow direction
changes during operation.
The direction of the hori-
zontal vane cannot be ad-
justed with the remote con-
troller.

Water leaks from the out-
door unit.

White smoke is discharged
from the outdoor unit.

Air does not blow out soon
in the heating operation.

The operation is stopped
for about 10 minutes in the
heating operation.

Hissing sound is some-
times heard.

The room cannot be heated
sufficiently.

In a multi-unit system, the
indoor unit which is not op-
erating becomes warm and
a sound, similar to water
flowing, is heard from the
unit.

The air conditioner starts
the operation only with the
main power turned on,
though you do not operate
the unit with the remote
controller.

Answer (not a malfunction)

• When the air conditioner is operated in COOL

or DRY mode, if the operation continues with air
blowing down for 1 hour, the direction of the air
flow is automatically set to horizontal to prevent
condensed water from dropping.

• In the heating operation, if the air flow tempera-

ture is too low or when defrosting is being done,
the horizontal vane position is automatically set
to horizontal.

• During COOL and DRY operations, pipe or pipe

connecting sections are cooled and this causes
water to condense.

• In the heating operation, the defrosting opera-

tion makes water frozen on the outdoor unit melt
and drip down.

• In the heating operation, water condensed on

the heat exchanger drips down.

• In the heating operation, vapor generated by the

defrosting operation looks like white smoke.

• Please wait as the air conditioner is preparing

to blow out warm air.

• Defrosting of the outdoor unit is being done (De-

frosting operation).
Since this is completed in 10 minutes, please
wait. (When the external temperature is too low
and humidity is too high, frost is formed.)

• This is the sound when the flow of refrigerant

inside the air conditioner is switched.

• When the outside air temperature is low, the

heating effect may not be sufficient.

• A small amount of refrigerant continues to flow

into the indoor unit even though it is not operat-
ing.

• These models are equipped with an auto restart

function. When the main power is turned off with-
out stopping the air conditioner with the remote
controller and is turned on again, the air condi-
tioner will start operation automatically in the
same mode as the one set with the remote con-
troller just before the shutoff of the main power.

Even if the above items are checked, when the air conditioner does not
recover from the trouble, stop using the air conditioner and consult your
dealer.

In the following cases, stop using the air conditioner and consult your dealer.

When water leaks or drops from the indoor unit.

When the left operation indicator lamp blinks.

When the breaker trips frequently.

The remote control signal may not be received in a room where an electronic
ON/OFF type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used.

Operation of the air conditioner may interfere with radio or TV reception in
areas where the reception is weak. An amplifier may be required for the af-
fected device.

When thunder is heard, stop operation and disconnect the power supply plug
or turn off the breaker. Otherwise, the electrical parts may be damaged.

Содержание MSZ-A09YV SERIES

Страница 1: ...r gli utenti Per utilizzare correttamente quest unità leggere questo libretto d istruzioni atten tamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË INSTRUÇÕES DE OPERAÇÃO Para os clientes Para utilizar esta unidade correctamente certifique se de que lê estas instruções de operação antes da utiliza...

Страница 2: ...ing the unit etc This may cause an injury etc if you fall down Do not pull the power supply cord The core wire of the power supply cord may be disconnected and this may cause a fire Do not charge or disassemble the batteries and do not throw them into a fire This may result in leakage fire or an explosion Do not operate the unit for a long time in high humidity e g leaving a door or window open In...

Страница 3: ...ade the insulation This may cause an electric shock Do not step or put anything on the indoor outdoor unit This may cause an injury etc if you or something falls down WARNING Consult your dealer for installation of the air conditioner CAUTION Do not install the unit where flammable gas could leak If gas leaks and collects around the unit it may cause an explosion Earth the unit Do not connect the ...

Страница 4: ... because the setting of the unit needs to be changed Auto restart function is When the indoor unit is controlled with the remote controller the operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to start operating in the same mode as the one set with the re...

Страница 5: ...nce in case of EMERGENCY HEAT MODE or twice in case of EMERGENCY COOL MODE Operation Indicator Operation Indicator Operation Indicator EMERGENCY HEAT EMERGENCY COOL STOP Handling of the remote controller The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the in door unit When a button is pressed one or two beeps will be heard from the indoor unit...

Страница 6: ...emperature is 2 C higher than the set temperature the set temperature may not be changed since the air conditioner is operating to reach the target set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than the set temperature the set temperature may not be chang...

Страница 7: ... in sequence I FEEL AUTO COOL DRY HEAT To stop operation Press the ON OFF button After the operation mode is set once the operation starts in the same mode as the one set previously from the next time by simply pressing the ON OFF button MANUAL OPERATION COOL DRY HEAT ON OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR MIN AMPM CLOCK C AMPM I FEEL COOL DRY AUTO HEAT RESET CLOCK ON OFF ...

Страница 8: ...c How to set the ON timer 1 Press the START button during operation Each time the button is pressed the ON timer mode alternates between ON and OFF 2 Set the time of the timer using the HR and MIN buttons Each time the HR button is pressed the set time in creases by 1 hour each time the MIN button is pressed the set time increases by 10 minutes To release the ON timer Press the START button How to...

Страница 9: ...d both ends of the front panel lift the panel up until its level and then pull it to wards you CAUTION Do not drop the front panel or pull it out forcibly The panel may be damaged Do not step onto an unstable bench when removing or installing the front panel This may cause an injury etc if you fall down 2 Wipe the front panel with a soft dry cloth or wash it with water After washing the panel wipe...

Страница 10: ...l ter with water If the dirt is noticeable wash the filter with a solu tion of mild detergent diluted in lukewarm water If hot water 50 C or more is used the filter may be deformed Open the front panel then remove replace the filter Catechin air filter Remove Install What is Catechin air filter The air filter is dyed with a natural material catechin that is contained in tea The catechin air filter...

Страница 11: ...rmed and the vanes may not work properly Put the vertical vanes back correctly to their original positions Otherwise condensed water may drip down from the indoor unit or the horizontal vanes could malfunction 6 Install the horizontal vanes Reverse the removal procedures Upper vane Lower vane Insert this end first Upper right Insert this end first Lower right After Cleaning Insert the power supply...

Страница 12: ... power failure as these models are equipped with an auto restart function the air conditioner should start operating again Refer to Descrip tion of AUTO RESTART FUNCTION on page 6 Question The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor...

Страница 13: ...akage or not when repairs are carried out The refrigerant charged in the air conditioner is safe Refrigerant normally does not leak however if refrigerant gas leaks indoors and comes into contact with the fire of a fan heater space heater stove etc harmful substances will be generated Electrical work Provide an exclusive circuit for the power supply of the air conditioner Be sure to observe the br...

Страница 14: ...310 JAPAN SG79Y280H01 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Страница 15: ......

Отзывы: