44
2. Checking mis-wiring and serial signal error.
MSZ-A09RV -
MSZ-A12RV -
Outdoor unit does not operate. When the operation indicator lamp (on the left-hand side) flashes on and off continuously
or only once.
E1
E1
1. Turn OFF power supply.
2. Turn ON power supply.
3. Press the EMERGENCY OPERATION switch.
Is the self-check function of indoor unit indicated when relay 52C turns ON
3min. later?
w
Short circuit of JPS (one-hour short circuit jumber cable) and JPG (GND
resistance) enables self-check function to be indicated within 3 min.
Is there indoor-outdoor mis-wiring,
poor contact, or disconnection?
Is there approx. 220-240V AC between outdoor
terminal block
2
and
1
?
Is mis-wiring or
serial signal error
indicated when
relay 52C turns
ON 3 min. later?
Is there 370V DC between both ends of
smoothing capacitor(C62) on the electronic
control P.C. board?
Replace in-out connecting
wire.
Does Power monitor lamp (on the right-hand
side) flash on and off when OPERATE/STOP
button on remote controller is pressed?
w
1 If there is any error in
serial signal system, the
mis-wiring indication will
appear by turning the
power off and then
turning it back
w
2 Mis-wiring may damage the electronic
control P.C. board during the operation in
the left. Be sure to confirm the wiring is
correct before the operation starts.
w
3 Replace indoor
electronic control
P.C. board.
w
3 Be sure to release the
failure-mode recall function
after checking.
w
The serial signal indication on the Power
monitor lamp (right side) facilitates
checking abnormality, based on the
failure-mode
Mis-wiring indication
No
No
Yes
Correct wiring
Replace outdoor electronic control P.C. board.
· Main circuit
· Reactor
· Noise filter P.C.
board
· Connection of
connector
Yes
A
B
Turn off power supply and confirm that indoor-outdoor
wiring is correct.
Short-circuit indoor terminal block
N
and
3
.
While pressing OPERATE-STOP button on remote
controller, press RESET button.
(The above procedure allows Power monitor lamp to
indicate the failure-mode)
w
2
Open-circuit indoor terminal block
N
and
3
,
Check if there is amplitude of 5 to 10VDC between outdoor
terminal block
N
and
3
(for confirmation of serial signal) and if there is 220-240V
AC between
2
and
N
1. Unplug the power cord.
2. Disconnect the connector between compressor and
transistor module.
3.Plug the power cord.
4. Press EMERGENCY OPERATION switch.
2.5 seconds OFF
ON
ON
Serial signal error indication
defective
Yes
No
Yes
Yes
No
Yes
No
(light up or OFF)
· Turn off inverter-
controlled
lighting
equipment.
· Plug the power
cord.
· Press
EMERGENCY
OPERATION
switch.
A
B
· Keep the unit
away from
fluorescent
light.
· Attach a filter
to light-
intercepting
part.
Green Sign
flash
21 22
24
30
29
28
27
26
25
23