11-2 Troubleshooting procedure
The following procedure facilitates identifying defective points.
The abnormalities in
can be located in the Troubleshooting check table on page 42~43.
Indoor unit dose
not respond to
remote controller.
Refer to
G
‘Check of
indoor electronic control
P.C. board’ on page 49.
Power monitor
lamp flashes.
Indoor unit does not respond to
remote controller. In addition,
operation Power monitor lamp
dose not light up, with
emergency operation switch ON.
Indoor fan motor
dose not run.
Refer to
F
‘Check of
indoor fan motor’ on
page 49.
Cause:indoor/outdoor
unit
· Mis-wiring
· Serial signal error
Cause: in Indoor unit
· Indoor coil thermistor
abnormality
· Room temperature
thermistor abnormality
· Auxiliary indoor coil
thermistor abnormality
Cause: in outdoor unit
· Outdoor power
system abnormality
· Outdoor unit
temperature
thermistor
abnormality
·Outdoor converter
power system
7 flashes
2.5 seconds OFF
Cause: in outdoor unit
· Outdoor control system
error
w
In case of serial signal
error, the mis-wiring
indication will appear
by turning the power
off and then turning it
back on.
5 flashes
2.5 seconds OFF
6 flashes
2.5 seconds OFF
12 flashes
2.5seconds OFF
Operation start
1 flash
2.5 seconds
or
0.5 seconds
OFF
Refer
H
‘Check of indoor
electronic P.C. board’ on
page 50.
2 flashes
2.5 seconds OFF
Refer to
‘Checking serial
signal error’ on
page 44.
Check
indoor/outdoor
Mis-wiring on
page 44.
Indoor coil thermistor
Room temperature
thermistor Auxiliary
indoor coil thermistor
Refer to
I
‘Check of
outdoor
thermistors’ on
Inverter/Compressor
Refer to
A
~
E
‘Compressor’ on
page 47 and 48.
Refer to
A
~
E
‘Transistior module’
on page 47 and 48.
Refer to
L
'Check
of power supply' on
page 52.
Outdoor electronic
control P.C. board.
Refer to
J
‘Check
of Reversing valve
coil’ on page 51.
Refer to
K
‘Check
of outdoor fan
motor’ on page 51.
Outdoor
electronic
control P.C.
board.
3 flashes
2.5 seconds OFF
Refer to
N
‘Check of
electronic control P.C. board
in the outdoor unit’ on page
Refer to
P
‘Check of
linear expansion valve
(LEV)’ on page 53.