30
COOL and DRY
HEAT
About 100
-
About 150
-
Horizontal AIR FLOW blowing range
7 Horizontal AIR FLOW (
)
The auto vane angle changes as follows by pressing the VANE CONTROL (
) button.
●
Press the “
” button.
The vertical vanes begin moving.
●
When the vanes move to the desired position, press the “
” button again.
The vanes stop moving.
NOTE
If the “
” button is not pressed again within 30 seconds in COOL or DRY mode or within 1 minute in HEAT mode
after the vanes start moving, the vanes will automatically return to their original positions.
8. Cold air prevention in HEAT mode.
When either of the following conditions occurs in HEAT mode, the auto vane angle changes to Angle 1 automatically to
prevent cold air blowing on users.
①
Compressor is not operating.
➁
Defrosting is performed.
➂
Indoor coil thermistor RT12 reads 24
:
or below.
➃
Indoor coil temperature is raising from 24°C or below, but it does not exceed 28
:
.
(8) ECONO COOL (
) operation
When the ECONO COOL button is pressed in MANUAL COOL mode, the horizontal vane swings in various cycle
according to the temperature of indoor heat exchanger(RT12).
Also SET TEMPERATURE is automatically set 2°C higher than that in MANUAL COOL mode.
•SWING operation
In swing operation of ECONO COOL operation air flow is initially blew out upward(levelly).
According to the temperature of indoor coil thermistor RT12 at starting of this operation, next downward blow time is
decided.Then when the downward blow has been finished,next upward blow time is decided. The air conditioner
repeats the swing operation in various cycle as follows.
However, for initial 10 min. the swing operation is performed in table G~H for quick cooling(but G : RT 12 is 24
:
or
less).
Also, after 10 min. when the difference of set temperature and room temperature is more than 2 degrees, the swing
operation is performed in table D~H for more cooling(but D: RT12 is 20
:
or less).
Temperature of indoor
coil thermistor RT12
more than 24°C
5
2
Downward blow time
(sec.)
22°C to 24°C
21°C to 22°C
20°C to 21°C
18
°C to
20
°C
17°C to 18°C
15°C to 17°C
15°C or less
5
8
11
14
17
20
23
Upward(level) blow time
(sec.)
20
17
14
11
8
2
23
A
H
G
F
E
D
C
B
•ECONOmical operation (SET TEMPERATURE)
When this operation is selected in MANUAL COOL mode, SET TEMPERATURE is automatically set 2°C higher than
that in MANUAL COOL mode.
By above SWING operation temperature that you feel can decrease by 2°C.
So keeping comfort, energy can be saved.