35
6-10. Outdoor low pressure and outdoor unit current
1. 09-class unit in single operation (OUTDOOR UNIT : MXZ30TN MXZ30TN2)
(1) COOL operation
1
Data is based on the condition of indoor
humidity 50%
<How to work fixed-frequency operation>
1.Set emergency switch to COOL or HEAT.The switch is locat-
ed on indoor unit.
2.Press emergency run ON/OFF button.
3.Compressor starts running at 33Hz (COOL) or 45Hz (HEAT).
4.Indoor fan runs at High speed and continues for 30 minutes.
5.To cancel this operation,press emergency run ON/OFF button
or any button on remote controller.
2
Air flow speed : High
3
Inverter output frequency : 33Hz
①
➁
Data is based on the condition of outdoor
humidity 75%.
Set air flow to High speed.
Inverter output frequency is 45Hz.
➂
(2) HEAT operation
65 70 75 80 85 90 95 100 105 110 115
50
60
70
80
90
100
Ambient temperature(
°
F)
(
°
F)
86
80
75
70
Indoor DB temperature(
°
F)
65 70 75 80 85 90 95 100 105 110 115
0.0
1.0
2.0
3.0
4.0
5.0
6.0
Ambient temperature(
°
F)
(
°
F)
15 20 25 30 35 40 45 50 55 60 65 70 75
4.0
5.0
6.0
7.0
8.0
9.0
Outdoor ambient temperature(
°
F)
Outdoor low pressure
Outdoor unit current (A)
Outdoor unit current (A)
45Hz
(PSIG)
33Hz
33Hz
65
75
70
86
80
75
70
Indoor DB temperature(
°
F)
Indoor DB temperature(
°
F)
OB275--2.qxp 03.12.2 16:50 Page 35