75
TROUBLESHOOTING
12
3. Troubleshooting procedure
1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality.
To make sure, check how many times the abnormality indication is flashing on and off before starting service work.
2) Before servicing check that the connector and terminal are connected properly.
3) If the electronic control P.C. board is supposed to be defective, check the copper foil pattern for disconnection and
the components for bursting and discoloration.
4) When troubleshooting, refer to the flow chart on page 76, 77 and the check table on page 78, 79, 80.
4. How to replace batteries
Weak batteries may cause the remote controller malfunction.
In this case, the remote controller can be repaired only by the battery replacement. To operate the remote controller nor-
mally, replace the batteries in the following order.
This remote controller has the RESET button. After refilling new batteries, press the RESET button with tip end of ball
point pen or the like, and then use the remote controller.
1
Remove the front lid and replace batteries.
Then re-attach the front lid.
2
Press the RESET button.
NOTE : If the RESET button is not pressed, the remote controller may not operate correctly.
Insert the negative pole
of the batteries first.
Check if the polarity of
the batteries are correct.
RESET button
Lead wiring
Housing point
12-1. Cautions on troubleshooting
1. Before troubleshooting, check the following:
1) Check the power supply voltage.
2) Check the indoor/outdoor connecting wire for mis-wiring.
2. Take care the following during servicing.
1) Before servicing the air conditioner, first be sure to turn off the remote controller to stop the unit, and then after con-
firming the horizontal vane is closed, turn off the breaker and/or disconnect the power plug.
2) Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic
control P.C. board.
3) When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the
components.
4) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.
MSH09TW
MSH12TN
MSH15TN
MSH17TN
MSH09TW -
MSH12TN -
MSH15TN -
MSH17TN -
U1
U1
U1
U1
MUH09TW
MUH12TN
MUH15TN
MUH17TN
MXZ30TN
MXZ30TN2
MUH09TW -
MUH12TN -
MUH15TN -
MUH17TN -
U1
U1
U1
U1
MUH12TN -
MUH15TN -
U2
U2
OB275--3.qxp 03.12.2 5:19 PM Page 75