11
SPECIFICATIONS
5
NOTE : Test conditions are based on ARI 210/240.
❈
1 : Rating conditions (cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, (75˚FWB)
(heating) — Indoor : 70˚FDB, 60˚FWB, Outdoor : 47˚FDB, 43˚FWB
❈
2 :
(heating) — Indoor : 70˚FDB, 60˚FWB, Outdoor : 17˚FDB, 15˚FWB
❈
3 :
(cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 82˚FDB, 65˚FWB
Operating Range
Item
Model
MSH09TW -
Capacity
Power
consumption
EER [SEER]
HSPF IV(V)
COP
INDOOR UNIT MODEL
External finish
Power supply
Max. fuse size (time delay)/ Disconnect switch
Min. circuit ampacity
Fan motor
Auxiliary heater
Airflow Low—Med.—High
Moisture removal
Sound level Low-Med.-High
Cond. drain connection O.D.
Dimensions
Weight
OUTDOOR UNIT MODEL
External finish
Power supply
Max. fuse size (time delay)
Min. circuit ampacity
Fan motor
Compressor
Refrigerant control
Sound level
Defrost method
Dimensions
Weight
REMOTE CONTROLLER
Control voltage (by built-in transformer)
REFRIGERANT PIPING
Pipe size
(Min. wall thickness)
Connection method
Between the indoor
& outdoor units
Refrigerant charge (R22)
Refrigerating oil (Model)
Btu/h
Btu/h
Btu/h
W
W
V, phase, Hz
A
A
F.L.A
A(kW)
CFM
CFM
pt./h
dB(A)
in.
in.
in.
in.
Ib.
V, phase, Hz
A
A
F.L.A
R.L.A
L.R.A
dB(A)
in.
in.
in.
Ib.
in.
in.
ft.
ft.
lb.
oz.
8,800
10,500
5,300
890
890
820
9.9 [10.0]
6.8 (5.9)
3.46
White
115, 1, 60
15
0.5
0.37
–
198-244-297
173(145)-226(187)-279(233)
2.3
26-31-36
5/8
33-1/2
7-1/2
10-15/16
20
Munsell 5Y 7/1
115, 1, 60
20
16
0.60
RH140WGJT
C-R 0.83 C-S 1.48
12.0
42.0
Capillary tube
47
Reverse cycle
30-23/32
10-1/32
21-1/4
82
Wireless type
12V DC
Not supplied (optional parts)
1/4 (0.0265)
3/8 (0.0285)
Flared
Flared
Max. 25
Max. 49
2 Ib. 3 oz.
9.3 (MS56)
❈
1
❈
3
❈
1
❈
1
❈
2
❈
1
❈
1
❈
2
Cooling
Heating 47
Heating 17
Cooling
Heating 47
Heating 17
Cooling
Heating
Heating
MSH09TW
MSH09TW -
MSH09TW
U1
U1
MUH09TW -
MUH09TW
U1
HEAT Dry
COOL Dry(Wet)
W
D
H
Model
Winding resistance (at 68˚F)
Ω
W
D
H
Liquid
Gas
Indoor
Outdoor
Height difference
Piping length
❈
1
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
Indoor intake air temperature
95˚FDB, 71˚FWB
67˚FDB, 57˚FWB
80˚FDB, 67˚FWB
70˚FDB, 60˚FWB
Outdoor intake air temperature
115˚FDB
67˚FDB
75˚FDB, 65˚FWB
17˚FDB, 15˚FWB