8
WIRING DIAGRAM
6
MSH-GA50VB
MSH-GA60VB
1.About the outdoor side electric wiring refer to the outdoor unit electric wiring diagram for servicing.
2.Use copper conductors only. (For field wiring)
3.Symbols below indicate.
: Connector
: Terminal block
NOTES:
SYMBOL
C11
F11
HIC1
MF
NAME
INDOOR FAN CAPACITOR
FUSE (3.15A)
DC/DC CONVERTER
INDOOR FAN MOTOR (INNER FUSE)
SYMBOL
MV1
MV2
NR11
RT11
NAME
VANE MOTOR (HORIZONTAL)
VANE MOTOR (VERTICAL)
VARISTOR
ROOM TEMPERATURE THERMISTOR
SYMBOL
RT12
SR141
TB
NAME
INDOOR COIL THERMISTOR
SOLID STATE RELAY
TERMINAL BLOCK
TB
TAB12
3
3
REMOTE
CONTROLLER
RECEIVER
P.C.BOARD
DISPLAY
P.C.BOARD
102
CN
101
CN
RED
BLU
MV2
CN201
3
2
1
BRN
L
N
3
F11
ELECTRONIC CONTROL
P.C. BOARD
NR11
CN211
CN
111
RT11
RT12
15
MV2
CN
151
CN112
1
2
MV1
HIC1
C11
121
CN
1
3
4
SR141
3
MF
RED
WHT
BRN
YLW
GRY
BLK
GRN/YL
W
BLU
PE
BRN
TO OUTDOOR
UNIT
CONNECTING
12V
1
2
3
4
5
6
CIRCUIT
BREAKER
POWER
SUPPLY
CORD
~/N 230V
50Hz
12V
TO OUTDOOR
UNIT
CONNECTING
BRN
BLU
GRN/YL
W
BLK
GRY
YLW
BRN
WHT
RED
MF
3
SR141
4
3
1
CN
121
C11
HIC1
MV1
RT13
4
3
2
1
CN112
151
CN
MV2
15
RT12
RT11
111
CN
CN211
NR11
ELECTRONIC CONTROL
P.C. BOARD
F11
3
N
L
BRN
1
2
3
CN201
MV2
BLU
RED
CN
101
CN
102
DISPLAY
P.C.BOARD
RECEIVER
P.C.BOARD
REMOTE
CONTROLLER
3
3
TAB12
TB
PE
CIRCUIT
BREAKER
POWER
SUPPLY
CORD
~/N 230V
50Hz
1.About the outdoor side electric wiring refer to the outdoor unit electric wiring diagram for servicing.
2.Use copper conductors only. (For field wiring)
3.Symbols below indicate.
: Connector
: Terminal block
NOTES:
SYMBOL
SR141
TB
SYMBOL
MV2
NR11
RT11
RT12
RT13
SYMBOL
C11
F11
HIC1
MF
MV1
INDOOR FAN CAPACITOR
FUSE(3.15A)
DC/DC CONVERTER
INDOOR FAN MOTOR(INNER PROTECTOR)
VANE MOTOR(HORIZONTAL)
VANE MOTOR(VERTICAL)
VARISTOR
ROOM TEMPERATURE THERMISTOR
INDOOR COIL THERMISTOR (MAIN)
INDOOR COIL THERMISTOR (SUB)
SOLID STATE RELAY
TERMINAL BLOCK
NAME
NAME
NAME
MSH-GA80VB
OB367D-1.qxp 12.1.13 7:49 AM Page 8
OB367D