5
SPECIFICATION
3
Indoor model
Function
Power supply
Air flow (High/Med./Low)
Breaker capacity
Running current
Power input
Power factor
Fan motor current
Model
Winding
resistance (at 20
:
)
Dimensions W
O
H
O
D
Weight
Air direction
Sound level (High/Med./Low)
Fan speed (High/Med./Low)
Fan speed regulator
Thermistor RT11 (at 25
:
)
Thermistor RT12 (at 25
:
)
Remote controller model
K
/h
A
A
W
%
A
"
mm
kg
dB
rpm
k
"
k
"
MSH-GA50VB
Single phase
230V, 50Hz
768/642/528
10
0.3
60
87
0.30
RC4V32-AA
WHT-BLK 293
BLK-RED 146
1,100
O
325
O
258
16
5
42/38/34
1,070/920/780
3
10
10
KP0A, KM04A
Cooling
Heating
MSH-GA60VB
Single phase
230V, 50Hz
10
0.3
60
87
0.30
RC4V32-AA
WHT-BLK 293
BLK-RED 146
1,100
O
325
O
258
16
5
3
10
10
KP0A, KM04A
Cooling
768/672/588
45/41/37
1,070/960/850
Heating
768/642/528
45/40/34
1,070/920/780
Electr
ical
data
F
an
motor
Special
remar
ks
Capacity
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor
Dry-bulb temperature 27
:
Wet-bulb temperature 19
:
Outdoor Dry-bulb temperature 35
:
Wet-bulb temperature (24
:
)
Heating : Indoor
Dry-bulb temperature 20
:
Wet-bulb temperature 15.5
:
Outdoor Dry-bulb temperature 7
:
Wet-bulb temperature 6
:
Indoor-Outdoor piping length : 5m
Indoor model
Function
Power supply
Air flow (High/Med./Low)
Breaker capacity
Running current
Power input
Power factor
Fan motor current
Model
Winding
resistance (at 20
:
)
Dimensions W
O
H
O
D
Weight
Air direction
Sound level (High/Med./Low)
Fan speed (High/Med./Low)
Fan speed regulator
Thermistor RT11 (at 25
:
)
Thermistor RT12 (at 25
:
)
Thermistor RT13 (at 25
:
)
Remote controller model
K
/h
A
A
W
%
A
"
mm
kg
dB
rpm
k
"
k
"
k
"
MSH-GA80VB
Single phase
230V, 50Hz
10
0.34
69
88
0.34
RC4V40-AA
WHT-BLK 138.2
BLK-RED 159.0
1,100
O
325
O
258
16
5
47/42/37
3
10
10
10
KP0A, KM04A
Cooling
960/822/684
1,310/1,130/970
Heating
960/834/732
1,310/1,150/1,020
Electr
ical
data
F
an
motor
Special
remar
ks
Capacity
OB367D-1.qxp 12.1.13 7:49 AM Page 5
OB367D