OC193-23
WIRING DIAGRAM
8
MODEL PCH24EK
1
WIRING DIAGRAM
LOSSNAY
CN2L
SW17
SW18
ON
OFF
87654321
87654321
ON
OFF
TB6
R.B
1
2
5
6
2
1
BLK
BLK
RED
WHT
YLW
GRY
BLK
RED
X4
X5
X6
AC
208V
WHT
RED
YL
W
GRN
GRN
RED
X3
X5
X4
F
ZNR
SW3
SW1
SW2
4 3 2 1
3 2 1
OUTDOOR
CN30
REMOCON
POWER
CN40
TO
REMOCON
CN22
TRANS
VANE
M3
M1M0
S R
5 4 3 2 1
CN50
DRAIN
CN20
INTAKE
CN21
PIPE
OFF
ON
YL
W
ORN
ORN
BLK
BRN
BLK
TH1
TH2
4
2
MF
C
MV
T
POWER SUPPLY
208/230V 60Hz
1 PHASE
L2
L1
BLK
TB1
3
BRN
2
BLU
BLU
TB3
TB2
GROUND
TRANSMISSION WIRES
DC12V
INDOOR UNIT
REMO
TE CONTR
OLLER
I.B
2
1
2
1
9
2
ORN
1
2 1
RED
ORN
654321
987654321
4321
4321
4321
X6
X2
1
YLW
TO OUTDOOR UNIT
CONNECTING WIRES
DC12V(polar)
D.U.M
CN27
M2
LOUVER
GR
Y
GR
Y
ML
5 1
1
2
VANE
POSITION
CN23
RED
BLK
WHT
BLU
BRN
BRN
4 3
BLK
BLK
6 5
2 1
HEATER
CN24
LS
10
SW5 SW6
CENTRALLY
CONTROL
CN51
X2
X3
YL
W
3
1
2
WHT
AC
230V
YL
W
YL
W
88H
RED
BLK
4
6
FS
H
5
3
88H
88H
4 3 2 1
TRANS
CN4T
BRN
BRN
RED
RED
A
C11V
A
C15.5V
8
3
1
26H
7
8
RED
BRN
BRN
GR
Y
GR
Y
YL
W
BLK
BLU
BRN
WHT
RED
ORN
BLK
BLK
GRN
CN2
CN1
1
2
3
1
2
3
4
5
SYMBOL
C
CN1<R.B>
CN2<R.B>
CN27<I.B>
CN51<I.B>
CN2L<I.B>
F<I.B>
FS
H
I.B
LS
MF
NAME
FAN MOTOR CAPACITOR
PROGRAM TIMER CONNECTOR
REMOTE SWITCH CONNECTOR
DRAIN UP MECHA. CONNECTOR
CENTRALLY CONTROL CONNECTOR
LOSSNAY CONNECTOR
FUSE (6A)
THERMAL FUSE (196˚F 15A)
HEATER ELEMENT
INDOOR CONTROLLER BOARD
LIMIT SWITCH
FAN MOTOR (INNER THERMOSTAT)
SYMBOL
ML
MV
R.B
TH1
TH2
SW1<I.B>
SW2<I.B>
SW3<I.B>
SW5<I.B>
SW6<I.B>
NAME
LOUVER MOTOR
VANE MOTOR
REMOTE CONTROLLER BOARD
ROOM TEMPERATURE
THERMISTOR(32˚F/15k
"
, 77˚F/5.4k
"
)
PIPE TEMPERATURE
THERMISTOR(32˚F/15k
"
, 77˚F/5.4k
"
)
MODEL SELECTOR SWITCH
ADDRESS SELECTOR SWITCH
EMERGENCY OPERATION SWITCH
MODEL SELECTOR SWITCH
MODEL SELECTOR SWITCH
SYMBOL
SW17<R.B>
SW18<R.B>
T
TB1~6
X2<I.B>
X3<I.B>
X4<I.B>
X5<I.B>
X6<I.B>
ZNR
26H
88H
NAME
ADDRESS SELECTOR SWITCH
FUNCTION SELECTOR SWITCH
TRANSFORMER
TERMINAL BLOCK
LOUVER MOTOR RELAY
VANE MOTOR RELAY
FAN MOTOR RELAY
FAN MOTOR RELAY
FAN MOTOR RELAY
VARISTOR
HEATER THERMAL SWITCH
HEATER CONTACTOR
NOTES:
1.Since the indoor transformer (T) is connected with 230V power, if 208V power is used, change the wiring connection in the following procedure.
Indoor side transformer (T) for 208V YELLOW
208V RED
230V YELLOW
Indoor fan (MF) for 208V
BLACK
208V BLACK
230V YELLOW
2.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
3.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal.
4.Symbols used in wiring diagram above are, :Terminal block, :connector, :PC board insertion tab.
5.Emergency operation
If a trouble occurs with either the remote controller or the indoor microcomputer and no other trouble exists, emergency operation for cooling or
heating can be performed by changing the setting of dip switch (SW3(I.B)) on the indoor controller board (emergency dry operation is not possible).
Содержание Mr.Slim PLH42AK
Страница 2: ......
Страница 22: ...OC193 20 6 OUTLINES AND DIMENSIONS Indoor unit PCH24 30EK1 Unit inch ...
Страница 23: ...OC193 21 Indoor unit PCH36 42EK1 Unit inch ...
Страница 72: ......