3. SIGNALS AND WIRING
3 - 19
3.8.2 MR-J4-_B_-RJ/MR-J4-DU_B_-RJ
(1) Safety observation function control by input device
The following connection diagram shows an operation of the safety observation function using input
devices assigned to pins of the CN10A and CN10B connectors with a safety controller. By diagnosis of
input signals, the servo amplifier complies with safety level Category 4, PL e, SIL 3.
A1
(24V)
A2
(0V)
24 V
0 V
FLEXB
US+
FLEXB
US+
24 V
0 V
X1
X2
A1
(24V)
Q1
Q2
Q3
A2
(0V)
WS0-CPU0
WS0-XTIO
CN10A
CN10B
S1
CN10A
CN10B
DO24VA
DO24VB
DO_A
DO_B
DICOMA
DI_A
DICOMB
DI_B
CN1A
CN1/2
MR-D30
MR-J4-_B_-RJ/
MR-J4-DU_B_-RJ
KM1
X00
COM
I1
I2
I3
I4
Application
Application
Control circuit
Safety observation function
Servo
motor
Servo system
controller
IO unit
QX_
Deceleration
command
KM1: Magnetic contactor
S1: Safety switch
Safety controller MELSEC-WS series
CPU module WSO-CPU0
Safety I/O combined module WS0-XTIO
SSCNET III/H