![Mitsubishi Electric MELSERVO MR-J4-B-LL Series Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-b-ll-series/melservo-mr-j4-b-ll-series_instruction-manual_239177039.webp)
2. SIGNALS AND WIRING
2 - 8
2.4.2 Output device
(1) Output device pin
The following shows the output device pins and parameters for assigning devices.
Connector pin No.
Parameter
Initial device
I/O division
CN3-13 [Pr.
PD07] MBR
DO-1
CN3-9 [Pr.
PD08] INP
(2) Output device explanations
Device
Symbol
Function and application
Electromagnetic
brake interlock
MBR
When using the device, set operation delay time of the electromagnetic brake in [Pr. PC02].
When a servo-off status or alarm occurs, MBR will turn off.
Malfunction
ALM
When using the signal, enable it by setting [Pr. PD07] and [Pr. PD08].
When the protective circuit is activated to shut off the base circuit, ALM will turn off.
When an alarm does not occur, ALM will turn on in 2.5 s to 3.5 s after power-on.
In-position
INP
When the number of droop pulses is in the in-position range, INP will turn on. The in-position range
can be changed with [Pr. PA10]. When the in-position range is increased, INP may be always on
during low-speed rotation.
The device cannot be used in the speed control mode and the pressure control mode.
Dynamic brake
interlock
DB
When using the signal, enable it by setting [Pr. PD07] and [Pr. PD08].
When the dynamic brake needs to operate, DB will turn off. When using the external dynamic
brake with the servo amplifier of 11 kW or more, this device is required. (Refer to section 11.17 of
"MR-J4-_B_(-RJ) Servo Amplifier Instruction Manual" and section 9.3 of "MR-J4-DU_(-RJ)/MR-
CR55K_ Instruction Manual".)
For the servo amplifier of 7 kW or less, it is not necessary to use this device.
The external dynamic brake cannot be used with 11 kW or more servo amplifier for compliance
with SEMI-F47 standard. Do not assign DB (Dynamic brake interlock) in [Pr. PD07] to [Pr. PD08].
Doing so will cause the servo amplifier to become servo-off when an instantaneous power failure
occurs.
Ready
RD
When using the signal, enable it by setting [Pr. PD07] and [Pr. PD08].
When the servo-on is enabled and the servo amplifier is ready to operate, RD will turn on.
Speed reached
SA
When using the signal, enable it by setting [Pr. PD07] and [Pr. PD08].
SA will turn off during servo-off. When the servo motor speed reaches the following range, SA will
turn on.
Set speed ± ((Set speed × 0.05) + 20) r/min
When the preset speed is 20 r/min or less, SA always turns on.
The device cannot be used in the position control mode and the pressure control mode.