1. FUNCTIONS AND CONFIGURATION
1 - 11
(b) 400 V class
Model MR-J4-DU_-LL
30KB4
37KB4
45KB4
55KB4
Output
Rated voltage
3-phase 323 V AC
Rated current
[A]
87
102
131
143
Main circuit power supply input
The main circuit power of the drive unit is supplied by the converter unit.
Control circuit power
supply input
Voltage/Frequency
1-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
Rated current
[A]
0.2
Permissible voltage
fluctuation
1-phase 323 V AC to 528 V AC
Permissible frequency
fluctuation
Within ±5%
Power consumption
[W]
45
Inrush current
[A]
Refer to section 8.4 of "MR-J4-DU_(-RJ)/MR-CR55K_ Instruction Manual".
Interface power
supply
Voltage
24 V DC ± 10%
Current capacity
[A]
(Note 1) 0.3 (including CN8 connector signals)
Control method
Sine-wave PWM control, current control method
Dynamic brake
External option (Note 5, 6)
SSCNET III/H communication cycle (Note 4)
0.222 ms, 0.444 ms, 0.888 ms
Fully closed loop control
Not available
Scale measurement function
Not available
Load-side encoder interface
Not available
Communication function
USB: connection to a personal computer or others (MR Configurator2-compatible)
Encoder output pulses
Not available
Analog monitor
Two channels
Analog input
Three points (±10 V)
Digital I/O
DI 1 point, DO 2 points
Protective functions
Overcurrent shut-off, overload shut-off (electronic thermal), servo motor overheat protection,
encoder error protection, undervoltage protection, instantaneous power failure protection,
overspeed protection, and error excessive protection
Functional safety
STO (IEC/EN 61800-5-2)
Safety performance
Standards certified by CB
EN ISO 13849-1 category 3 PL d, IEC 61508 SIL 2, EN 62061 SIL CL2, EN 61800-5-2
Response performance
8 ms or less (STO input off
→
energy shut off)
(Note 2) Test pulse input
(STO)
Test pulse interval: 1 Hz to 25 Hz
Test pulse off time: Up to 1 ms
Mean time to dangerous
failure (MTTFd)
MTTFd
≥
100 [years] (314a)
Diagnostic coverage (DC)
DC = Medium, 97.6 [%]
Average probability of
dangerous failures per hour
(PFH)
PFH = 6.4 × 10
-9
[1/h]
Compliance to
global standards
CE marking
LVD: EN 61800-5-1
EMC: EN 61800-3
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
UL standard
UL 508C
Structure (IP rating)
Force cooling, open (IP20) (Note 3)
Environment
Ambient
temperature
Operation
0 °C to 55 °C (non-freezing)
Storage
-20 °C to 65 °C (non-freezing)
Ambient
humidity
Operation
90 %RH or less (non-condensing)
Storage
Ambience
Indoors (no direct sunlight),
free from corrosive gas, flammable gas, oil mist, dust, and dirt
Altitude
2000 m or less above sea level (Note 7)
Vibration resistance
5.9 m/s
2
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
Mass
[kg]
16
21