1. FUNCTIONS AND CONFIGURATION
1 - 8
Model MR-J4-_-LL
10B1
20B1
40B1
Environment
Ambient
temperature
Operation
0 °C to 55 °C (non-freezing)
Storage
-20 °C to 65 °C (non-freezing)
Ambient
humidity
Operation
90 %RH or less (non-condensing)
Storage
Ambience
Indoors (no direct sunlight),
free from corrosive gas, flammable gas, oil mist, dust, and dirt
Altitude
2000 m or less above sea level (Note 5)
Vibration resistance
5.9 m/s
2
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
Mass
[kg]
0.8
1.0
Note 1. 0.3 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifiers, operate them at the ambient temperatures of 0 °C to 45 °C or at 75% or smaller
effective load ratio.
3. Test pulse is a signal which instantaneously turns off a signal to the servo amplifier at a constant period for external circuit to
self-diagnose.
4. The communication cycle depends on the controller specifications and the number of axes connected.
5. Follow the restrictions in section 2.7 of "MR-J4-_B_(-RJ) Servo Amplifier Instruction Manual" when using the servo amplifiers
at altitude exceeding 1000 m and up to 2000 m above sea level.
Содержание MELSERVO MR-J4-B-LL Series
Страница 9: ...A 8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 20 MEMO ...
Страница 63: ...3 PARAMETERS 3 18 MEMO ...
Страница 71: ...4 PRESSURE LOOP GAIN ADJUSTMENT 4 8 MEMO ...
Страница 79: ...5 TROUBLESHOOTING 5 8 MEMO ...