9 PDS Control Objects
9.1 [Controlword (Obj. 6040h)]
77
9
9
PDS Control Objects
9.1
[Controlword (Obj. 6040h)]
[Controlword (Obj. 6040h: 00h)]
Description
PDS status switching command is given, or control commands are returned and set.
Use bit 0 to bit 3 and bit 7 in the PDS status transition.
■
[Bit 4: OMS]
*1 Available on servo amplifiers with firmware version A5 or later.
*2 Available on servo amplifiers with firmware version B0 or later.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U16
RW
RXMAP
0000h
0000h to FFFFh
Impossible
Bit
Name
Description
0
SO
Switch-on
1
EV
Enable voltage
2
QS
Quick stop
3
EO
Enable operation
4
OMS
Differs depending on the value of [Modes of operation (Obj. 6060h)]. Refer to the following for details.
5
OMS
Differs depending on the value of [Modes of operation]. Refer to the following for details.
6
OMS
Differs depending on the value of [Modes of operation]. Refer to the following for details.
7
FR
Fault reset
8
HALT
0: Operation ready
1: Pauses the operation according to [Halt option code (Obj. 6050h)].
Refer to the following for details.
9
OMS
Differs depending on the value of [Modes of operation]. Refer to the following for details.
10
11
12
13
14
15
Setting value
Symbol
Description
1 (pp)
New set-point
Obtains a new positioning parameter at bit rising
4 (tq)
6 (hm)
HOS
Homing operation start
0: Do not start homing procedure
1: Start or continue homing procedure
8 (csp)
9 (csv)
10 (cst)
-104 (ct)