8 Manufacturer Specific Control Object
8.28 [Phase current (Obj. 2C37h)]
59
8
8.28
[Phase current (Obj. 2C37h)]
[Phase current (Obj. 2C37h: 00h)]
Description
The total number of Sub Indexes (= 3) is returned.
[U phase current (Obj. 2C37h: 01h)]
Description
The U-phase current value is displayed in increments of 0.1 % in relation to the rated current as 100 %.
[V phase current (Obj. 2C37h: 02h)]
Description
The V-phase current value is displayed in increments of 0.1 % in relation to the rated current as 100 %.
[W phase current (Obj. 2C37h: 03h)]
Description
The W-phase current value is displayed in increments of 0.1 % in relation to the rated current as 100 %.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RO
Impossible
3 (fixed)
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
TXMAP
-32768 to 32767
0.1 %
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
TXMAP
-32768 to 32767
0.1 %
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
TXMAP
-32768 to 32767
0.1 %
Impossible