2 General Objects
2.7 [Restore default parameters (Obj. 1011h)]
19
2
2.7
[Restore default parameters (Obj. 1011h)]
[Restore default parameters (Obj. 1011h: 00h)]
Description
The total number of Sub Indexes is returned.
[Restore all default parameters (Obj. 1011h: 01h)]
Description
All parameters (servo parameters and network parameters) that can be stored in the non-volatile memory can be reset to the
factory setting. To reset the servo parameters and network parameters to the factory setting, write "64616F6Ch" (= reverse
order of ASCII code of "load") in this object, and cycle the power or reset the software.
When a multi-axis servo amplifier is used, the servo parameters of all axes are initialized.
The read value is always "1" (initializing values).
2.8
[Identity Object (Obj. 1018h)]
[Identity Object (Obj. 1018h: 00h)]
Description
The total number of Sub Indexes is returned.
[Vendor ID (Obj. 1018h: 01h)]
Description
The vendor ID of the servo amplifier is returned.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RO
Impossible
Impossible
Default
Range
Description
01h
01h (fixed)
Sub Index 1 is supported.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RW
Impossible
00000001h
00000000h to
FFFFFFFFh
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RO
Impossible
04h
04h (fixed)
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RO
Impossible
00000002h
(fixed)
Impossible