102
14 Homing Mode Objects
14.1 [Home offset (Obj. 607Ch)]
14
Homing Mode Objects
14.1
[Home offset (Obj. 607Ch)]
[Home offset (Obj. 607Ch: 00h)]
Description
Set the difference between zero position of the machine coordinate system and homing position.
14.2
[Homing method (Obj. 6098h)]
[Homing method (Obj. 6098h: 00h)]
Description
Set a homing method.
14.3
[Homing speeds (Obj. 6099h)]
[Homing speeds (Obj. 6099h: 00h)]
Description
The total number of Sub Indexes (= 2) is returned.
[Speed during search for switch (Obj. 6099h: 01h)]
Description
Set the servo motor speed for homing. If [Pr. PT02.7 Internal position command - Process speed selection] is set to "0" and
the set speed exceeds 8000 r/min (or mm/s), the servo motor speed is clamped at 8000 r/min (or mm/s). When changing the
maximum value of "Range" to the permissible speed, set [Pr. PA28.4 Speed range limit selection] to "1". The description of the
object varies as shown in the table below, depending on the combination of the setting of [Pr. PT01.1 Speed/acceleration/
deceleration unit selection] and the connected servo motor.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I32
RW
TXMAP
0
-2147483648 to
2147483647
pos units
Possible
[Pr. PT08]
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I8
RW
RXMAP
37
-43 to 37
Possible
[Pr. PT45]
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RO
Impossible
2
2 (fixed)
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RW
RXMAP
Refer to the
following.
0 to maximum
speed
vel units
Possible
Refer to the
following.
[Pr. PT01.1]
Connected servo motor
Default
Units
Parameter
0 (encoder unit)
Rotary servo motor
10000
0.01 r/min
[Pr. PT05]
Linear servo motor
0.01 mm/s
1 (command unit)
500000
pulse/s
[Pr. PV11]