![Mitsubishi Electric MELSEC iQ-RD77GF16 Скачать руководство пользователя страница 94](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-rd77gf16/melsec-iq-rd77gf16_user-manual_239146094.webp)
92
APPX
Appendix 1 Component List of the RD77MS
■
Q170ENCCBL_M-A
• Model explanation
• Connection diagram
When fabricating a cable, use the recommended wire and connector set MR-J3CN2 for encoder cable given above, and make
the cable as shown in the following connection diagram. Maximum cable length is 50 m (164.04 ft.).
Type: Q170ENCCBL_M - A
2
Cable length [m (ft.)]
5
Symbol
10
20
30
2 (6.56)
5 (16.40)
10 (32.81)
20 (65.62)
30 (98.43)
50
50 (164.04)
:
:
:
2
LG
4
MRR2
6
8
MDR2
10
1
P5
3
MR2
5
7
MD2
9
BAT
MR-J4-B-RJ
Q171ENC-W8
B
A
CN2L
A
G
T
P
F
J
E
L
M
C
S
R
H
D
N
K
B
U
V
MR
MRR
K
L
M
N
SHD
P
R
LG
S
P5
T
MD
MDR
BAT
A
B
C
D
E
F
G
H
J
LG 2
BAT
MR2
3
MRR2
4
MD2
7
MDR2
8
P5
R
E
K
L
H
J
S
N
BAT
MR
MRR
MD
MDR
LG
P5
SHD
1
9
CN2L connector
Pin arrangement
View A
50 m (164.04 ft.) or less
Synchronous
encoder
Encoder connector
Synchronous encoder cable
Encoder connector
Pin arrangement
View B
: Pin provided
: Pin not provided
Signal
Pin
Signal
Pin
Encoder side
MS3106B22-14S(plug)
MS3057-12A(cable clump)
Cable length 50 m (164.04 ft.) or less
SD plate
Servo amplifier side
36210-0100PL(plug)
36310-3200-008(shell)
: Twisted pair cable
Twisted pair for signal
(BAT/LG, MR/MRR, MD/MDR)
Twisted pair (P5/LG)
Cable cross-section
diagram
Wire the cable as shown in figure below so that twisted
pair for signal do not touch.
Core