![Mitsubishi Electric MELSEC iQ-RD77GF16 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-rd77gf16/melsec-iq-rd77gf16_user-manual_239146043.webp)
3 FUNCTION LIST
3.2 Combination of Main Functions and Sub Functions
41
3
: Combination possible
: Combination limited
: Combination not possible
*1 Change the current value using the positioning data. Disabled for a start of positioning start No. 9003.
Main functions
Functions
related to
positioning
start
Functions related to
positioning stop
Other functions
Pre-reading
start function
Step function
Stop
command
processing
for
deceleration
stop function
Skip function
M code output
function
Home
position
return
control
Machine home position return control
[RD77MS]
[RD77GF]
Fast home position return control
Major
positioning
control
Position
control
1-axis linear control
2-, 3-, or 4-axis linear
interpolation control
1-axis fixed-feed control
2-, 3-, or 4-axis fixed-feed
control (interpolation)
2-axis circular interpolation
control
3-axis helical interpolation
control
Speed control (1- to 4-axis)
Speed-position switching control
Position-speed switching control
Other
control
Current value changing
NOP instruction
JUMP instruction
LOOP to LEND
Manual
control
JOG operation, inching operation
Manual pulse generator operation
Expansion
control
Speed-torque control
Advanced synchronous control (output
axis)
Содержание MELSEC iQ-RD77GF16
Страница 2: ......
Страница 76: ...74 7 OPERATION EXAMPLES 7 1 Operation Examples Positioning start No setting program ...
Страница 78: ...76 7 OPERATION EXAMPLES 7 1 Operation Examples JOG operation execution program RD77MS example ...
Страница 115: ......