![Mitsubishi Electric MELSEC iQ-RD77GF16 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-rd77gf16/melsec-iq-rd77gf16_user-manual_239146035.webp)
3 FUNCTION LIST
3.1 Control Functions
33
3
In "major positioning control" ("high-level positioning control"), "Operation pattern" can be set to designate whether to continue
executing positioning data. Outlines of the "operation patterns" are given below.
Manual
control
JOG operation
Outputs a command to servo amplifier while the JOG start signal is ON.
Inching operation
Outputs commands corresponding to minute movement amount by manual operation to servo
amplifier.
(Performs fine adjustment with the JOG start signal.)
Manual pulse generator operation
Outputs pulses commanded with the manual pulse generator to servo amplifier.
Inter-module synchronization function
Synchronizes the control timings among multiple modules on the same base.
Expansion
control
Speed-torque control
Carries out the speed control or torque control that does not include the position loop for the
command to servo amplifier by switching control mode.
Advanced synchronous control
Carries out the synchronous control that synchronizes with input axis by setting the system such as
gear, shaft, change gear and cam to the "advanced synchronous control parameter".
[Da.1] Operation pattern
Details
Independent positioning control (positioning complete)
When "independent positioning control" is set for the operation pattern of the started positioning
data, only the designated positioning data will be executed, and then the positioning will end.
Continuous positioning control
When "continuous positioning control" is set for the operation pattern of the started positioning data,
after the designated positioning data is executed, the program will stop once, and then the next
following positioning data will be executed.
Continuous path control
When "continuous path control" is set for the operation pattern of the started positioning data, the
designated positioning data will be executed, and then without decelerating, the next following
positioning data will be executed.
Main functions
Details
Содержание MELSEC iQ-RD77GF16