6. Status Display and Parameter Setting
6
−
18
(1) Control input
1) Control input 1 L,
H
0
Ready ON command
8
Torque limit 1
1
Servo ON command
9
Torque limit 2
2
A
Torque limit 3
3
B
4
C
5
D
6
Parameter conversion command
E
L
7
Servo alarm reset command
H
F
Cutting
2) Control input 2 L,
H
0 8
1 9
2 A
3 B
4 C
5 D
6 E
L
7
∗
Not used.
H
F
∗
Not used.
3) Control input 3 L,
H
0
Spindle control mode selection
command 1
8
Forward run start command
1
Spindle control mode selection
command 2
9
Reverse run start command
2
Spindle control mode selection
command 3
A
Index forward run command
3
Spindle control mode selection
command 4
B
Index reverse run command
4
Spindle control mode selection
command 5
C
Orientation start command
5
Gear selection command 1
D
6
Gear selection command 2
E
Sub-motor selection command (during
1-amplifier 2-motor changeover)
L
7
Gear selection command 3
H
F