![Mitsubishi Electric FX3U-1PG Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/mitsubishi-electric/fx3u-1pg/fx3u-1pg_user-manual_238960076.webp)
7 Buffer Memory
7.3 Positioning Parameters
70
FX
3U
-1PG User's Manual
7.3.23 [BFM#51] Acceleration time
The time required to accelerate from the bias speed to the maximum speed is set.
→
For details on the acceleration time, refer to Section 6.2.
Point
When the positioning parameter is used, use the acceleration/deceleration time (BFM#15). However, the
acceleration time and the deceleration time cannot be set individually.
7.3.24 [BFM#52] Deceleration time
Set the time required from the maximum speed to the bias speed.
→
For details on the deceleration time, refer to Section 6.2.
Point
When the positioning parameter is used, use the acceleration/deceleration time (BFM#15). However, the
acceleration time and the deceleration time cannot be set individually.
BFM No.
Description
R/W
Default
High order
16bit
Low order
16bit
-
#51
Setting range:
Trapezoidal acceleration/deceleration: 1 to 32,767 ms
Approximate S-shaped acceleration/deceleration: 1 to 5,000 ms
However, the acceleration and deceleration times are the same when using approximate
S-shaped acceleration/deceleration.
R/W
K100
BFM No.
Description
R/W
Default
High order
16bit
Low order
16bit
-
#52
Setting range:
Trapezoidal acceleration/deceleration: 1 to 32,767 ms
Approximate S-shaped acceleration/deceleration: Same as acceleration time
R/W
K100