10 Program Example
10.3 Sequence Program
117
FX
3U
-1PG User's Manual
1
Introduc
tion
2
Speci
ficati
on
3
Sy
stem
Configurati
on
4
Ins
tallati
on
5
Wi
rin
g
6
Be
fore Starti
ng
Po
sition
ing
Operation
7
Buf
fer M
emory
8
Man
ual
C
ontrol
9
Posi
tioni
ng
Co
ntrol
10
Program
Ex
ampl
e
M8000
M8000
T0
X007
From previous page
From previous page
RUN monitor
RUN monitor
X006
X005
X004
M8000
M8000
RUN monitor
RUN monitor
M4
M5
M7
M8
M6
M9
M10
M11
M13
M12
M15
M14
FNC 12
MOV
K4M0
U0\G25
FNC 12
DMOV
U0\G26
D10
FNC 12
MOV
U0\G28
K4M20
FNC 12
DMOV
U0\G58
D20
FNC 12
DMOV
U0\G60
D30
END
1-speed positioning
operation start
Not
used
Interrupt 1-speed
positioning operation start
2-speed positioning
operation start
External command
positioning operation start
Variable speed
operation
Writing of operation command
Reading of current address
Relative address
Interrupt stop
operation start
Interrupt 2-speed
positioning operation start
Data-set type mechanical
zero return operation start
Reading of status information
Reading of current address
(pulse converted value)
Reading of current value of
operation speed
DOG type mechanical zero
return operation start
Reverse JOG operation
Forward JOG operation
Содержание FX3U-1PG