6 Before Starting Positioning Operation
6.5 Handling the STOP Command
38
FX
3U
-1PG User's Manual
6.5.2
Remaining distance operation
When the STOP command is used to stop the positioning operation, the restart operation changes depending
on the STOP input mode (BFM#3 b15 or BFM#37 b15) setting.
When the STOP input mode is OFF, the remaining distance operation is executed by the restart command.
After the positioning operation completes, the positioning completion flag turns ON.
When the STOP input mode is ON, the remaining distance operation is not executed, and the positioning
ends at the stop position. The positioning completion flag remains off.
1. Positioning operations where remaining distance operation is possible
2. Operation
Operations applicable to the remaining
distance operation
Operations not applicable to the remaining
distance operation
1-speed positioning operation
JOG operation
2-speed positioning operation
DOG type mechanical zero return (high speed)
Interrupt stop operation
DOG type mechanical zero return (creep)
-
Data-set type mechanical zero return
-
Interrupt 1-speed positioning operation
-
External command positioning operation
-
Variable speed operation
-
Interrupt 2-speed positioning operation
Remaining
distance
Operation speed I
Speed
Time
1-speed positioning
operation start
(BFM#25 b8)
STOP command
(BFM#25 b1)
READY
(BFM#28 b0)
Remaining distance
operation waiting
(BFM#28 b12)
Positioning
completion flag
(BFM#28 b8)
Bias speed
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON