9 Positioning Control
9.8 Interrupt 2-speed Positioning Operation
109
FX
3U
-1PG User's Manual
1
Introduc
tion
2
Speci
ficati
on
3
Sy
stem
Configurati
on
4
Ins
tallati
on
5
Wi
rin
g
6
Be
fore Starti
ng
Po
sition
ing
Operation
7
Buf
fer M
emory
8
Man
ual
C
ontrol
9
Posi
tioni
ng
Co
ntrol
10
Program
Ex
ampl
e
2. Address specification
Is handled as a relative address (the travel amount is specified by using the distance from the current
address.)
(Even when an absolute address is specified, it is treated as a relative address.)
3. Rotation direction
The operation direction is determined by the sign (positive/negative) of target address I.
When the target address I sign is positive: Forward
When the target address I sign is negative: Reverse
4. 1-speed completion flag
• Conditions to turn on
- When interrupt input 0 is detected
• Conditions to turn off
- When the positioning completes
- When the operation stops by an error
- When the operation sops by the STOP command
5. Positioning completion flag
The positioning completion flag turns off when the operation starts.
When the interrupt input 1 is detected, and the operation reaches to the target address I, the positioning
completion flag turns on.
6. Interrupt input 0, Interrupt input 1
The contents of the interrupt input 0, the interrupt input 1, and the detection edge change as follows
depending on the interrupt input setting, the DOG input polarity, and the STOP input polarity settings.
Point
• When interrupt input 0 and interrupt input 1 are on at the start of the positioning operation and the rising
edge is the detection edge, interrupt input 0 and interrupt input 1 become valid when their signals turns
OFF and then ON again, respectively.
• When interrupt input 0 and interrupt input 1 are off at the start of the positioning operation and the falling
edge is the detection edge, interrupt input 0 and interrupt input 1 become valid when their signals turns ON
and then OFF again, respectively.
Interrupt input setting
(BFM#3 b3, b2 or
BFM#37 b3, b2)
DOG input polarity
(BFM#3 b12 or
BFM#37 b12)
STOP input polarity
(BFM#3 b14 or
BFM#37 b14)
Interrupt input 0:
Detection edge
Interrupt input 1:
Detection edge
(0, 0)
0
0
DOG: Rising edge
STOP (Terminal):
Rising edge
(0, 0)
0
1
DOG: Rising edge
STOP (Terminal):
Falling edge
(0, 0)
1
0
DOG: Falling edge
STOP (Terminal):
Rising edge
(0, 0)
1
1
DOG: Falling edge
STOP (Terminal):
Falling edge
(0, 1)
0
-
DOG: Rising edge
INT1: Rising edge
(0, 1)
1
-
DOG: Falling edge
INT1: Rising edge
(1, 0)
-
0
INT0: Rising edge
STOP (Terminal):
Rising edge
(1, 0)
-
1
INT0: Rising edge
STOP (Terminal):
Falling edge
(1, 1)
-
-
INT0: Rising edge
INT1: Rising edge