34
Start/stop from the operation panel (PU
3.4.2
Use the setting dial like a potentiometer to perform operation.
POINT
Set "0" (extended mode parameter valid) in
Pr. 160 User group read selection
.
Set "1" (setting dial potentiometer mode) in
Pr. 161 Frequency setting/key lock operation selection
.
Operation example Change the frequency from 0Hz to 50Hz during operation
REMARKS
· If flickering "50.00" turns to "0.0", the
Pr. 161 Frequency setting/key lock operation selection
setting may not be "1".
· Independently of whether the inverter is running or at a stop, the frequency can be set by merely turning
.
Display
Operation
PU indication is lit.
Flicker ··· Parameter setting complete!!
7.
Press to set.
The parameter number
previously read appears.
1.
Screen at powering on
The monitor display appears.
2.
Press to choose the PU operation
mode.
3.
Press to choose the parameter
setting mode.
11.
Turn until "50.00" appears.
The flickering frequency is the set frequency.
You need not press .
The frequency flickers for about 5s.
Flicker ··· Parameter setting complete!!
8.
Change Pr. 161 to the setting value of " "
in the similar manner. (Refer to step 4 to 7.)
9.
Mode/monitor check
Press twice to choose
monitor/frequency monitor.
10.
Press (or ) to start the inverter.
4.
Turn until (
Pr. 160
) appears.
5.
Press to read the currently set value.
" " (initial value) appears.
6.
Turn to change it to
the setting value " ".