GOT-F900 SERIES (CONNECTION)
Connection of Peripheral Equipment 6
6-9
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on o
f
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
o
n
n
e
c
ti
on
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
6.4
Caution on Use of Peripheral Equipment
When connecting a personal computer to the GOT in order to transfer screen data or sequence program
or to monitor the personal computer, observe the following cautions on use.
6.4.1
Caution when connecting the GOT and PLC via RS-232C port
(Only in case of the F920GOT-K, F930GOT, F930GOT-K, or F940GOT)
If the GOT-F900 (which is equipped with one RS-422 port and one RS-232C port) has already been set
to connect with the PLC using the RS-232C port, the data transfer screen is not displayed automatically
even when a personal computer is connected to the RS-232C port instead of the PLC (due to the RS-
232C port priority).
To eliminate the inconvenience described below, it is recommended to use the GOT-F900 with two RS-
232C ports. (Available only in certain models)
Follow the procedures below and changeover the screen manually from SELECT MODE to DATA
TRANSFER in order to transfer screen data.
Operating procedures
1) While pressing and holding the upper left corner of the screen, turn on the power. Keep
holding for a while.
2) The "LANGUAGE" screen appears. Press "END".
3) The "SET-UP MODE" screen appears. Press "END"
4) The "SELECT MODE" screen appears. Press "OTHER MODE".
5) The "OTHER MODE" screen appears. Press "DATA TRANSFER".
6) Transfer screen data.
RS-232C port function priority
The setting for the function with higher priority is confirmed first. If the function has been set, the one
with lower priority is not executed.
For example, if a connected equipment (PLC) or bar code reader is set valid, screen data transfer or
sequence program transfer and monitor is not enabled because those functions have lower priority as
shown in the table.
*1 Available only in the FX, A, or QnA, Q Series CPU direct connection (including the QnA or Q serial
communication).
However, when using the F920GOT-K, available only in the FX Series CPU direct connection.
Rank order
RS-232C functions
1
Connected equipment (PLC, general-purpose equipment)
2
Bar code reader
3
Printer
4
2-port interface function
*1
5
Screen data transfer mode
RS-232C
Personal computer
RS-232C
PLC
GOT-F900
GOT-F900 Not automatically
changed over.
GOT-F900
DATA
TRANSFER
The connected equipment is changed.
Содержание F920GOT-BBD-K-E
Страница 4: ...GOT F900 SERIES CONNECTION ii ...
Страница 6: ...GOT F900 SERIES CONNECTION iv ...
Страница 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Страница 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Страница 102: ...GOT F900 SERIES CONNECTION Installation and Wiring of F920GOT K F930GOT K F940 W GOT 4 4 32 MEMO ...
Страница 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Страница 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Страница 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Страница 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Страница 338: ...GOT F900 SERIES CONNECTION Connection of FX Series Positioning Unit FX 2N 10 20GM 12 12 16 MEMO ...
Страница 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Страница 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Страница 460: ...GOT F900 SERIES CONNECTION Connection of FLEX PC N Series PLC Manufactured by Fuji Electric 16 16 18 MEMO ...
Страница 478: ...GOT F900 SERIES CONNECTION Connection of Machine Controller CP9200SH PLC Manufactured by Yaskawa Electric 17 17 18 MEMO ...
Страница 500: ...GOT F900 SERIES CONNECTION Connection of FP Series PLC Manufactured by Matsushita Electric Works 18 18 22 MEMO ...
Страница 522: ...GOT F900 SERIES CONNECTION Connection of SLC500 MicroLogix Series PLC Manufactured by Allen Bradley 19 19 22 MEMO ...
Страница 546: ...GOT F900 SERIES CONNECTION Connection of SIMATIC S7 200 300 400 Series PLC Manufactured by Siemens AG 20 20 24 MEMO ...
Страница 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Страница 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Страница 591: ......