Model name
EHWT17D-MHEDW
Dimensions
Height
mm
1750
Width
mm
595
Depth
mm
680
Casing
Munsell
-
6.2PB 9/0.9
RAL code
-
260 90 05
Material
-
Pre-coated metal
Product weight (empty)
kg
166
Product weight (full)
kg
345
Gross weight
kg
183
Water volume of heating circuit in the unit *1
L
5.47
Brine/Water volume of ambient loop circuit in the unit
L
3.16
Type of Installation
-
Floor standing
Electrical data
Heat pump
(exclude immersion
heater)
Power supply
Ph
~/N
V
230
Hz
50
Breaker
A
16
Booster heater
Power supply
Ph
-
V
-
Hz
-
Capacity
kW
-
Heater step
-
-
Current
A
-
Breaker
A
-
Immersion heater
Power supply
Ph
~/N
V
230
Hz
50
Capacity
kW
3
Current
A
13
Breaker
A
16
Water circulation
pump
(Primary circuit)
Performance
curve:
please refer
to section 4.6.4
Type
DC motor
Input
(10/20/max L/min)
Speed 1
10/13/15
Speed 2
16/21/27
Speed 3
24/32/42
Speed 4
34/46/58
Speed 5
47/58/60
Current
(10/20/max L/min)
Speed 1
0.2/0.2/0.3
Speed 2
0.2/0.3/0.4
Speed 3
0.3/0.4/0.5
Speed 4
0.4/0.5/0.6
Speed 5
0.5/0.6/0.6
Water circulation
pump
(DHW circuit)
Input
Speed
55
Speed (Default setting)
69
Speed
80
Current
Speed
0.25
Speed (Default setting)
0.31
Speed
0.34
Flow rate
Speed
13.5
Speed (Default setting)
19.0
Speed
22.9
Flow rate
Primary circuit
Max.*2
L/min
27.7
Min.*3
L/min
7.1
Ambient loop
Max.*2
L/min
24.0
Min.*3
L/min
7.2
Heat exchanger
Ambient loop circuit - Refrigerant
-
MWA1-70PA
Refrigerant - Primary circuit water
-
MWA1-44PA
Primary circuit water - Domestic hot water
-
CBH18-18H
Domestic hot
water tank
Volume
L
170
Material
-
Duplex 2010 stainless
steel (EN10088)
Declared load profile
-
L
Average climate
η
wh
(water heating efficiency)
-
171
Water heater energy efficiency class
-
A+
Expansion vessel
(Primary circuit)
Volume
L
-
Charge pressure
MPa
-
Safety device
Primary circuit
Control thermistor
°C
1 to 80
Pressure relief valve
MPa
0.3
Flow sensor (Min. flow)
L/min
5.0
BH manual reset thermostat
°C
-
BH thermal Cut Off
°C
-
DHW tank
Control thermistor
°C
40 to 70
IH manual reset thermostat
°C
85
Temperature & pressure
relief valve
°C
90
MPa
0.7
Ambient loop
Control thermistor
°C
10 to 30
Flow switch (Min. flow)
L/min
5.5
Refrigerant circuit
Control thermistor (High)
°C
-20 to 125
Control thermistor (Low)
°C
-40 to 90
Pressure switch
MPa
4.14 ± 0.1
Pressure sensor
MPa
0 to 5.0
Connections
Water
Primary circuit
mm
φ28
DHW circuit
mm
φ22
Ambient loop
mm
φ22
Refrigerant
-
R32
Guaranteed
operating range
Ambient *4
°C
0 to 35
%RH
80
Water inlet temperature (Ambient loop)
°C
10 to 30
Min. Water outlet temperature (Ambient loop)
°C
4
Operating range Heating
Room temperature
°C
10 to 30
Flow temperature
°C
20 to 60
DHW
°C
40 to 60
Legionella prevention
°C
60 to 70
Sound power level
dB(A)
38
*1 Volume of sanitary water circuit is not included in this value.
*2 If the water flow rate exceeds maximum, the flow speed will be greater than 1.5 m/s, which could corrode the pipes.
*3 If the water flow is less than the minimum, the flow error will be activated.
*4 The environment must be frost-free.
2.4 Water to Water Heat Pump (WTW)
Specifications
2
B-23
Cylinder
unit/
Hydrobox/GSHP/WTW