DISASSEMBLY PROCEDURE
PHOTOS/FIGURES
87
OCH714D
20.
How to remove the scale trap (sanitary circuit)
(1) Remove the front panel. (Refer to Procedure 1.)
(2) Disconnect the CNP4 connector and the earth cable in
the control box. (Photo 4-1)
(3) Release the water pump lead wire from the cable clamp
and the cable strap in the control box, the cable strap,
the fastener and the band below the control box.
(Photos 4-1, 10-1 and 10-6)
(4) Remove the P-HEX (Water-Water). (Refer to Procedure
18.)
(5) Remove the water pump. (Refer to Procedure 19.)
(6) Rotate pipe (W.P. - Tank) side up.
(7) Remove the 3 screws (Right side) and screw (fixing the
S.T.-W.P. support). (Photos 20-1 and 20-2)
(8) Remove the scale trap with the S.T.-W.P. support. (Photo
20-2)
(9) Remove the
screws and the saddle band, then remove the
scale trap. (Photo 20-2)
• When reinstalling the G1" nut, use a new G1" gasket.
• Reuse the saddle band and the screws.
Photo 20-1
Photo 20-2
Scale trap
Water pump
Nut (G1")
Screws
Saddle band
Pipe (W.P.-Tank)
Screw fixing the
S.T.-W.P. support
Pipe (W.P. - Tank)
Quick connection
clip
Water pump
Gasket (G1")
P-HEX
(Water-Water)
Screw
(right side)
Screw
(right side)
Nut (G3/4")
Screw
(right side)
S.T.-W.P. support
Nut (G3/4")
Pipe
(tank-W.C.)