DISASSEMBLY PROCEDURE
PHOTOS/FIGURES
30. How to remove the zone1 flow water temp. & zone1 return
water temp. thermistors (THW6, THW7) /zone2 flow water
temp. & zone2 return water temp. thermistors (THW8,
THW9) (ERST17D-***BD model)
(1) Remove the front panel. (Refer to Procedure 1.)
(2) Disconnect the relay connector (THW6/7/8/9) under the
control box. (Photo 4-4)
(3) Release the water pump lead wire from the cable clamp,
the fastener and the cable strap in the control box, and the
cable strap, the fastener and the band below the control
-
box. (Photos 4-1, 10-6 and 30)
(4) Remove the thermistors from the thermistor holders. (Photo
30)
Photo 30
94
OCH714D
Thermistor <THW9>
Thermistor <THW7>
Thermistor <THW6>
Thermistor <THW8>
Band
Band