98
OCH714D
Commissioning/Field settings record sheet (continued from the previous page)
Main remote controller screen
Parameters
Default
setting
Field
setting Notes
Setting
Service
menu
Pump speed
DHW
Pump speed (1 to 5)
5
Heating/Cooling
Pump speed (1 to 5)
5
Heat source setting
Standard/Heater/Boiler/Hybrid *11
Standard
Heat pump setting
Heat pump flow rate
range
Minimum(0 to 100L/min)
5 L/min
Maximum(0 to 100L/min)
100 L/min
Quiet mode
Day (Mon to Sun)
—
Time
0:00 - 23:45
Quiet level (Normal/ Level1/ Level2)
Normal
Operation
settings
Heating operation
Flow temp.range
*12
Minimum.temp.(20 to 45°C)
30°C
Maximum.temp.(35 to 60°C)
50°C
Room temp.control
*13
Mode (Normal/Fast)
Normal
Interval (10 to 60min)
10min
Heat pump thermo
diff.adjust
On/Off *9
On
Lower limit (−9 to −1°C)
-5°C
Upper limit (+3 to +5°C)
5°C
Freeze stat function *14
Outdoor ambient temp. (3 to 20°C) / **
5°C
Simultaneous operation (DHW/Heating)
On/Off *9
Off
Outdoor ambient temp. (−30 to +10°C) *6
−15°C
Cold weather function
On/Off *9
Off
Outdoor ambient temp. (−30 to −10°C) *6
−15°C
Boiler operation
Hybrid settings Outdoor ambient temp.
(−30 to +10°C) *6
−15°C
Priority mode (Ambient/Cost/CO
2)
*15
Ambient
Outdoor ambient temp. rise
(+1
to
+5 °C)
+3 °C
Intelligent
settings
Energy
price
*16
Electricity
(0.001 to
999 */kWh)
0.5
*/kWh
Boiler
(0.001 to
999 */kWh)
0.5
*/kWh
CO
2
emis-
sion
Electricity
(0.001 to 999 kg -CO
2
/
kWh)
0.5 kg -CO
2
/kWh
Boiler
(0.001 to 999 kg -CO
2
/
kWh)
0.5 kg -CO
2
/kWh
Heat
source
Heat pump capacity
(1 to 40 kW)
11.2 kW
Boiler efficiency
(25 to 150%)
80%
Booster heater 1
capacity
(0 to 30 kW)
2 kW
Booster heater 2
capacity
(0 to 30 kW)
4 kW
Smart grid ready
DHW
On/Off
Off
Target temp (+1 to +20°C
) / -- (Non active)
--
Heating
On/Off
Off
Target temp.
Switch-on recommendation(20
to 60°C) 50°C
Switch-on command(20
to 60°C)
55°C
Cooling
On/Off
Off
Target temp.
Switch-on recommendation(5
to 25°C)
15°C
Switch-on command(5
to 25°C)
10°C
Pump cycles
Heating (On/Off)
On
Cooling (On/Off)
On
Interval(10 to 120 min)
10 min
Floor dry up function
On/Off *9
Off
Target temp.
Start&Finish (20 to 60°C)
30°C
Max. temp.
(20 to 60°C)
45°C
Max. temp. period
(1 to 20 days)
5 days
Flow temp.
(Increase)
Temp. increase step (+1 to +10°C)
+5°C
Increase interval (1 to 7 days)
2 days
Flow temp.
(Decrease)
Temp. decrease step (−1
to
−
10°C)
−
5°C
Decrease interval (1 to 7 days)
2 days
Summer mode
On/Off
Off
Outdoor
ambient temp.
Heating ON (4 to 19°C)
10°C
Heating OFF (5 to 20°C)
15°C
Judgement
time
Heating ON (1 to 48 hours)
6 hours
Heating OFF (1 to 48 hours)
6 hours
Forced heating ON (-30 to 10°C)
5 °C
Water flow control
On/Off
Off
(Continued to next page.)