59
Operations
ENGLISH
step
3.
Set the desired capacity.
• Set the remaining capacity of each device to
output signal.
Call Out Settings
This item is used to output warning signals from the CALL
OUT terminal to the device connected when the capacity be-
comes full or reaches to the speci
fi
ed value.
2
System
4
3
Call Out Settings
Setup Menu
Rear Terminal Setting
step
1.
Set the desired capacity for each area.
Off:
Does not output a signal.
“Alarm Recording Area” can be set when “Alarm Record-
ing Area” (
page 77 “Change Partition Setting”) is set
to other than “0 %.”
“LPA Recording Area” can be set when “Long Pre-Alarm
Area” (
page 77 “Change Partition Setting”) is set to
other than “0 %.”
Call out settings use the photo-coupler output to decrease
the malfunctions due to wiring. See “CALL OUT output
terminal” (
page 19) for the proper connection.
For the relationship between the warning display and
CALL OUT signal output,
see page 108. The warning
display of the item written “Fixed” in the CALL OUT output
column displays unconditionally. For the item written “Se-
lectable,” you can set the condition to output CALL OUT
signal.
For example, the buzzer can be set to sound when reach-
ing the value set in “Normal Recording Area,” “Alarm
Recording Area,” “LPA Recording Area,” or “Copy 2” while
“Buzzer” is set to “Warning.”
Key Sound
This item is used to make a sound when using the operation-
al buttons, JOG dial, and SHUTTLE ring.
System
4
3
Setup Menu
Rear Terminal Setting
step
1.
Set the key sound to on or off.
Buzzer
This item is used for a buzzer to sound when the remaining
main or copy 2 device capacity reaches the value set in “Low
Memory Alarm Setting” (
page 58). Other than the above,
it is possible to set the buzzer to sound when starting alarm
recording or emergency recording or when a warning is dis-
played.
To sound a buzzer only when reaching a speci
fi
ed remaining
HDD capacity:
1) Set “Buzzer” to “Remain.”
2) Set the remaining capacity in “Low Memory Alarm Set-
ting.”
To sound a buzzer when reaching the specified remaining
HDD capacity or when a warning is displayed:
1) Set “Buzzer” to “Warning.”
2) Set the remaining HDD capacity in the “Call Out Settings.”
System
4
3
Setup Menu
Rear Terminal Setting
step
1.
Set the desired buzzer setting.
SETTING
BUZZER
Remain
ON
OFF
OFF
OFF
Warning
OFF
ON
OFF
OFF
Alarm
OFF
OFF
ON
OFF
LAN
OFF
OFF
OFF
ON
Off
OFF
OFF
OFF
OFF
When reaching the remaining
capacity set in “Low Memory
Alarm Setting”
When a failure occurs and a
warning is displayed
When an alarm recording or
emergency recording is started
When controlling the buzzer to be
sound via the personal computer
When you set buzzer to “LAN,” the buzzer is controlled
remotely via RS-232C command, etc.
When “Triplex” is set to “Mode 3” or “Mode 5,” buzzer
does not sound. (
page 67.)