![Mitsubishi Electric AnyWire ASLINK Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/mitsubishi-electric/anywire-aslink/anywire-aslink_user-manual_238818014.webp)
12
TERMS
Unless otherwise specified, this manual uses the following terms.
GENERIC TERMS AND ABBREVIATIONS
Unless otherwise specified, this manual uses the following generic terms and abbreviations.
Term
Description
Address
Device information set to a slave module to identify each node on the AnyWireASLINK network
Address writer
A hand-held device to read/write parameters (including addresses) from/to a slave module
Alarm ID
An ID of a slave module where an alarm has occurred.
Note that if the alarm is for the NZ2AW1GNAL or the entire network, the alarm ID will be 0FFFH.
AnyWireASLINK
A system where sensors at the end of a control system are connected to a programmable controller in the most suitable
way.
With this system, the NZ2AW1GNAL can detect sensor disconnection and a user can set the I/O operations of a slave
module on the NZ2AW1GNAL without using I/O areas of the CPU module.
Authentication Class
A group of devices and switching hubs compatible with CC-Link IE TSN, classified according to the functions and
performance by the CC-Link Partner Association.
For authentication Class, refer to the CC-Link IE TSN Installation Manual (BAP-C3007ENG-001) published by the CC-
Link Partner Association.
Engineering tool
A tool used for setting up programmable controllers, programming, debugging, and maintenance.
ID
Information assigned to a module based on its address to identify whether it is an input module or output module
Link device
A device (RX, RY, RWr, RWw, LB, or LW) in a module on CC-Link IE TSN
Master station
A station that controls the entire network on CC-Link IE TSN. This station can perform cyclic transmission and transient
transmission with all stations.
Only one master station can be used in a network.
Power cable (24V, 0V)
A cable that connects a 24VDC external power supply to the NZ2AW1GNAL
Remote buffer memory
Buffer memory in a remote station on CC-Link IE TSN
Remote station
A station that exchanges I/O signals (bit data) and I/O data (word data) with the master station of CC-Link IE TSN by
cyclic transmission. This station can perform transient transmission.
Slave station
A station other than a master station on CC-Link IE TSN: a local station, a remote station
Terminating unit
A waveform shaper
Transmission cable (DP, DN)
A signal cable that connects between a slave module and the NZ2AW1GNAL
Transmission cycle time
A data sampling interval
Generic term/abbreviation
Description
ASLINKAMP
A generic term for sensor amplifiers that have an AnyWireASLINK interface
ASLINKER
A generic term for I/O devices that have an AnyWireASLINK interface
ASLINKSENSOR
A generic term for sensor modules that have an AnyWireASLINK interface
RWr
An abbreviation for a remote register of a link device. Word data input from a slave station to the master station. (For
some areas in a local station, data are input in the opposite direction.)
RWw
An abbreviation for a remote register of a link device. Word data output from the master station to a slave station. (For
some areas in a local station, data are output in the opposite direction.)
RX
An abbreviation for remote input of a link device. Bit data input from a slave station to the master station. (For some
areas in a local station, data are input in the opposite direction.)
RY
An abbreviation for remote output of a link device. Bit data output from the master station to a slave station. (For some
areas in a local station, data are output in the opposite direction.)
Slave module
A generic term for modules that communicate data with the NZ2AW1GNAL via AnyWireASLINK communication
Содержание AnyWire ASLINK
Страница 1: ...CC Link IE TSN AnyWireASLINK Bridge Module User s Manual NZ2AW1GNAL ...
Страница 2: ......
Страница 22: ...20 3 PROCEDURES BEFORE OPERATION MEMO ...
Страница 96: ...94 8 PROGRAMMING 8 2 Program Example Program ...
Страница 100: ...98 8 PROGRAMMING 8 2 Program Example Program ...
Страница 101: ...8 PROGRAMMING 8 2 Program Example 99 8 ...
Страница 193: ...APPX Appendix 8 External Dimensions 191 A Appendix 8 External Dimensions 43 86 16 8 102 3 6 3 4 0 2 Unit mm ...
Страница 199: ......