background image

USING THE SIP-DECT SITE 

SURVEY KIT

Содержание SIP-DECT Site Survey Kit

Страница 1: ...SIP DECT Site Survey Kit USER GUIDE...

Страница 2: ...ocument or new editions of it may be issued to incorporate such changes No part of this document can be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose w...

Страница 3: ...ll State 9 Audio Quality Measurements 10 Handover Menu 11 Planning and Site Survey 12 Ascertaining Customer Requirements 12 Initial Determination of Base Station Locations 12 Optimum Positioning of th...

Страница 4: ...SIP DECT Site Survey Kit User Guide iv Interference Factors 21 Reception Conditions 23 Using External Antennas 23 Fading Effect 24 APPENDIX A TECHNICAL DATA Technical specifications 26...

Страница 5: ...USING THE SIP DECT SITE SURVEY KIT...

Страница 6: ...SIP DECT Site Survey Kit User Guide 2...

Страница 7: ...DECT phones when activated Always observe the rules and regulations of the establishment concerned when using portable phones within medical facilities Never open the equipment itself touch the plug i...

Страница 8: ...SIP DECT SITE SURVEY KIT SIP DECT SITE SURVEY KIT CONTENTS SIP DECT Site Survey Kit Upper Layer SIP DECT Site Survey Kit Lower Layer The Tripod bag includes the tripod light stand with Powerpack brac...

Страница 9: ...2 Attach the Powerpack in bracket 3 Connect the PoE cable to the Powerpack use the standard RJ45 connector 4 Screw the DECT base station mounting plate on the tripod 5 Attach RFP SI with Status LED s...

Страница 10: ...with BNC connector 3 Connect the antenna cables to the DECT base station The DECT phone shows the standard measurement mode display with RFP Number RPN and field strength dBm Troubleshooting during St...

Страница 11: ...el 650c in the charger Wait until the Mitel 650c is fully charged Ensure that the Mitel 650c is switched off before placing it in the carrying case CHARGING THE IPOD The iPod can be charged with the L...

Страница 12: ...AND SOFTKEYS Standard display in idle state XQ mode This key toggles the XQ to OFF ON Default is ON and XQ is controlled by the DECT base statoin DECT measure mode All visible DECT base stations from...

Страница 13: ...can be changed manually In an active call between the measurement DECT phones you see the following Site survey On Off DECT XQ mode On Off Automatic handover On Off Line in On Off default Off headset...

Страница 14: ...ite 1 Define the first Mitel 650c as audio source 2 Toggle Line in ON in the Service menu 3 Connect the music player iPod via the audio cable 4 Toggle Line in OFF in the service menu of the second Mit...

Страница 15: ...the SIP DECT Site Survey Kit Handover menu in active call state Initiate Handover to by a long press on the star key only in call Toggle automatic handover On Off function by a long press on the hash...

Страница 16: ...nes distributed throughout the premises and which users are where Specify areas with a high traffic density Dynamics How many DECT phones are expected where and at what times of the day Recommendation...

Страница 17: ...dea of the equipment required and the locations for the base stations Co operation with the customer As soon as you are able to make sufficiently binding statements about problem areas you should invo...

Страница 18: ...base station Make sure the installation site is at a sufficient height to be protected from acts of vandalism DECT BASE STATION FOR INDOOR SUPPLY Observe the following principles when installing DECT...

Страница 19: ...ASE STATION SYNCHRONIZATION TDM and IP Base stations To guarantee a seamless handover the base stations should be fitted in such a way that the 60dBm overlap area is guaranteed When conducting survey...

Страница 20: ...eous connections are possible which require for example four base stations Thus approximately 60 DECT phones can be used in a hotspot with high traffic volume simultaneous call connections of approxim...

Страница 21: ...f the transmitter with the DECT phones until the limit value is shown on the display Enter these points on your floor plan TDM BASE STATIONS The selected limit value should be measured at these points...

Страница 22: ...ry the components must be positioned at a distance of at least 30 cm from the base station Likewise other metallic objects should be positioned as far away from the base station as possible Limit valu...

Страница 23: ...also customer satisfaction For new projects in particular the following considerations must be taken into account Radio coverage area capacity in terms of the number of connections traffic density Kno...

Страница 24: ...upply ranges for these independent DECT radio systems can also overlap In this case an automatic system search is not possible RADIO CHARACTERISTIC OF A BASE STATION The coverage range of a base stati...

Страница 25: ...n HIGH FREQUENCY PROPAGATION CONDITIONS For a better understanding of the explanations on physical conditions given in the following sections we first need to take a look at the basic principles of hi...

Страница 26: ...s and is therefore difficult to assess Metal paneled rooms and large metal clad objects such as air conditioners computer rooms and metallized glassed areas mirrored fire protection walls storage tank...

Страница 27: ...s are useful for rectifying radio signals thereby achieving a greater range in one particular direction e g to provide coverage to remote ancillary buildings providing coverage to an outside area with...