R000226 BP1 Automation
12
v.0.1 03/21
6
CONFIGURING PROJECTOR IMB
6.1 Configuring Barco ICMP-X in Series 2 and 3 Projectors
These instructions apply to the use of the MiT BP1 automation board used with a Barco
Alchemy ICMP-X server in the following projector models:
DP2K-B and DP4K-B
DP2K-BLP
and
DP4K-BLP
DP2K-C and DP2K-CLP
DP2K-E
DP4K-L
DP2K-S and DP2K-SLP
The BP1 and this procedure may work using earlier versions of the Alchemy (ICMP and
ICMP+), but it has not been tested with them.
This section assumes that the reader is trained and competent to install and configure
these projectors, and is familiar with the service technician functions of the Barco
Communicator software, and the ICMP-X’s web UI.
Parts and Tools Needed
A complete BP1 automation system (or an IMC3-J automation retrofitted with the
BP1 JNIOR replacement board as described in the Appendix).
Three cat 5e or cat 6 Ethernet patch cables, of sufficient length to connect the
modified ICM3-J to the card cage of the projector, plus a custom-pinned RJ45 male
to DB37 male cable, per Section 5.3.
A Windows or Mac computer with at least one wired NIC, and Barco Communicator
version 5.15.0 or later installed.
The password to put Barco Communicator into service technician mode.
Procedure:
1. Connect the cables between the BP1 and the projector as described in Section 5.2, if
they aren’t already.
2. To configure the Media Server (ICMP-X) Automation, open Barco Communicator,
connect to the projector, and put Barco Communicator into service technician mode.
Navigate to Media Server
→
Automation
→
Cues, as illustrated in Figure 6-1.