Section 3
Setting Up the Unit
• On firm level surface
• Free from flooding or sprinklers
• Near GFCI outlet
1.
Position Drum
• Lid Assembly in plastic enclosure
• Drum and pre-drilled lid
• Remote transmitter (remote receiver
and antenna inside enclosure)
• Soft drum lid cover
• Pump suction pipe and filter
• Auto-Drain valve assembly
•
Agitator j-tube and eductor (if “with
Agitator”)
• 4 each - bolts, flat washers, lock
washers, nuts
2.
Remove Lid
Assembly and
verify components
3.
Assemble Unit
• Align chassis with four holes (large
bung in front of controller)
• Insert ½” pump suction line into pump
• Insert ¼” black tubing of Auto Drain
valve assembly into pump discharge
•
If “with Agitator” unit, insert j-tube into
3/8” agitator valve fitting
• Secure chassis to lid using 7/16”
wrenches: sequence - bolt, chassis,
lid, flat washer, lock washer, nut
• Position lid assembly on drum
• Note: all holes oversized to ease
assembly
• GFCI Outlet
• 115 volts minimum. Confirm voltage
with multi-meter.
• 15 amp circuit required. Unit draws 9
amps when misting. Ensure total load
of unit plus all other devices on circuit
does not exceed breaker rating.
5.
Connect Electric
Power
4.
Connect Nozzle
Circuit
• To bulkhead fitting
• Install optional zone kit according to
instructions provided.
*Note: Instructions noted in italics are required for units supplied with
Agitating valves.
• Pressing Green
►
button will cycle through each of four System
Modes. The
▲
at the top of the display points to the active
System Mode.
1.OFF
– If equipped with agitation, unit will perform a daily
agitation cycle. Otherwise it will sit idle.
2.REM
– Unit will allow Remote and MANUAL MISTs, but no
AUTO MISTs. (For pre-2012 systems: displayed as ON)
3.AUTO-EVERYDAY
– Misting program runs daily. This is the
most commonly used System Mode.
4.AUTO-CUSTOM
– Misting program runs only on days set in
CUSTOM PGM menu.
• Pressing Red MENU/STOP button displays triangular cursor by
DAY/TIME position on left side of display. Use
▲
or
▼
buttons to
cycle through menu structure. Use Green
►
button to select menu
item and view or change data element within that item.
• Within a menu item, the convention is that the flashing data
element can be changed with the
▲
or
▼
buttons. Move to the
next data element with the Green
►
button.
• Exit the menu item by pressing the MENU button. The unit will
revert to previous System Mode in 3 minutes if the MENU button is
not pressed.
• Clear any error code by pressing the Red MENU/Stop button for 5
seconds. The System Mode will return to its previous state
(usually AUTO Everyday).
• To reset the controller to factory settings, unplug the unit, and hold
down MENU and the
▲
buttons while plugging the unit back in.
Mist Cycles, remote duration and number of nozzles must be
reentered.
Section 3
Setting Up the Unit
Using the Controller