There are a number of factors that influence consumption of 
the insecticide and timing for replenishment:

• Number of nozzles installed
• Minutes of scheduled misting per day
• Number and duration of remote mists
• Volume of the drum

The replenishment frequency for a common misting program 
can be read from the table below.  Locate the row that most 
closely corresponds to the number of nozzles that are 
installed and locate the column that most closely reflects the 
average daily mist duration (including remote activated mists.)  
The value in the table where the selected row and column 
intersects reflects the number of days the insecticide will last.

By example, a 40 nozzle system misting an average of 2 
minutes per day would consume the drum in 55 days.

To change assumptions about any of these variables, please 
visit 

http://www.mistaway.com/product-support-center.html 

to 

utilize the online Replenishment Frequency Calculator.

Days Until Empty Table

55 Gallon Drum 

Nozzle Flow Rate:  45 ml/min

20

151

109

73

30

101

73

49

40

76

55

36

50

61

44

29

60

50

36

24

70

43

31

21

Nozzles

2 min 

per day

3 min 

per day

Replenishment Frequency

Section 5

Managing the Insecticide

90sec 

per day

The Gen 1.3 controller stores a “virtual volume” representing the 
amount of dilute insecticide remaining in the drum.  Each time 
the unit mists, this “virtual volume” is reduced by a calculated 
estimate of the volume of dilute insecticide that was misted 
through the nozzle circuit.  When the “virtual volume” equals 0, 
EMP (Empty) is displayed on the controller, and it is time to 
replenish the insecticide.

Follow these steps to replenish the dilute insecticide in the 
drum:

1.

Remove the waterproof fabric cover from the drum top 
and remove the 2” cap on drum bung.

2.

Fill the drum half full with water, add insecticide 
concentrate, and then top off the drum.

Maintain an air gap of 6” between the tip of hose and 
the fluid level in the drum at all times.

Use a funnel to add insecticide concentrate – strictly 
following label instructions.  See Dosing and 
Replenishment Frequency Calculator at 

http://www.mistaway.com/product-support-center.html 

for further information.

Stop filling when the fluid level is 4” from the top.  
Replace cap on drum bung.

3.

Reset level indicator in the controller.

EMP(Empty) continues to appear in the display.  
Navigate to MAINTENANCE Menu, scroll to LEVEL.  
Depress Green 

button 5 seconds to enter routine.

Use 

or 

buttons to set level to full (8 bars)

Ensure the 

icon at top of display, indicating System 

Mode, is pointing to the desired mode, usually, AUTO 
Everyday.

4.

Replace fabric cover on drum top.

5.

Dispose of the empty bottle

:  Strictly follow label 

instructions regarding disposal of the empty bottle.  Most will 
require triple rinsing and puncturing the bottle.

Replenishing Insecticide Concentrate in Gen 1.3

Section 5

Managing the Insecticide

Содержание Drum-Based Misting Unit Gen 1.3

Страница 1: ...MistAway Drum Based Misting Unit Gen 1 3 Operations Manual Copyright 2013 by MistAway Systems Inc...

Страница 2: ...ds The unit will also mist in response to a signal from a handheld remote transmitter for a duration programmed by the user Base Functionality Optional Equipment and Functionality MistAway Drum Based...

Страница 3: ...lling Insecticide label and dilution statement should be securely attached to the unit reservoir in a weatherproof pouch Strictly follow label instructions regarding storage and disposal of insecticid...

Страница 4: ...or empowered to give any other warranty or to assume any other liability on behalf of MSI Warranty Conditions This warranty is extended only to the original Purchaser and is not transferable A purchas...

Страница 5: ...red for units supplied with Agitating valves Pressing Green button will cycle through each of four System Modes The at the top of the display points to the active System Mode 1 OFF If equipped with ag...

Страница 6: ...Menu LEVEL Press green button and use arrows to set level to full 8 bars Section 3 Setting Up the Unit Set Day and Time note AM and PM Exit by pressing Menu button a Set Day and Time SET UP Menu AGT S...

Страница 7: ...etting Up the Unit Clear area Pres MIST button on transmitter Unit will MIST If Remote Agitation RAG is set to a value greater than 0 system with Agitate AGT prior to MIST 12 Test by Activating Remote...

Страница 8: ...REMOTE MIST if the Remote Agitation Duration SET UP RAG is set to a value greater than 0 seconds NOTE on pre 2012 systems agitation duration before a remote mist is fixed at 15 seconds If a Zone Kit i...

Страница 9: ...xing guidance Conventional Insecticide Formulations Exempt or Green Insecticide Formulations Section 5 Managing the Insecticide It is important to note that there are differences of opinion among mist...

Страница 10: ...ists this virtual volume is reduced by a calculated estimate of the volume of dilute insecticide that was misted through the nozzle circuit When the virtual volume equals 0 EMP Empty is displayed on t...

Страница 11: ...ouling the intake filter or nozzle circuit Clean filter on pump intake line Remove filter from intake line Use wire brush and hose to remove debris 1 Flush pump and agitation valve if equipped and noz...

Страница 12: ...circuit to drain and cause ERR3 to be displayed That is the error condition does not occur while the user is on site troubleshooting the issue Leak Detection ERR3 MIST volume greater than expected Sec...

Страница 13: ...trical power is restored to the unit the digital controller will return into the same mode the unit was operating in prior to the power being turned off For example if the unit was in AUTO EVERYDAY mo...

Страница 14: ...n agitating valve a pressure gauge is mounted into the plastic housing Pump Intake Line and Filter Pump intake positioned near bottom of drum Filter ensures debris is not drawn into pump and nozzle ci...

Страница 15: ...on cycle prior to a remote mist cycle RAG not available on pre 2012 systems TNK Set reservoir size in gallons 5 995 SEN Turn optional wind sensor ON or OFF WND Set max wind speed above which wind sens...

Страница 16: ...s quickly INS Unit is in Inspection Mode and will mist for 5 minutes or until stopped MST Unit is misting NOZ00 Unit stopped operating because the number of nozzles is set to 0 Clear by pressing Red S...

Отзывы: