P A G E 9 O F 1 7
M I S S I ON S OL A R E NE R G Y L L C
ELECTRONIC
versions are uncontrolled except when accessed directly from document control directory. Printed copies are uncontrolled unless verified against online document.
C OP YR I GH T 2 0 2 0 M I S S IO N S OL A R E N ER GY L L C , AL L R I G H T S R ES E R V ED
REVISION: R2 RELEASE DATE: 9/25/2020
TABLE 4: ELECTRICAL RATINGS OF MSE PERC 60 (6BB, BLACK BACKSHEET) MODULE SERIES
Parameters
MSE330SX5T
MSE335SX5T
MSE340SX5T
MSE345SX5T
MSE350SX5T
Power Output
P
max
Wp
330
335
340
345
350
Tolerance
%
-0/+3
-0/+3
-0/+3
-0/+3
-0/+3
Open Circuit Voltage V
oc
V
40.40
40.58
40.82
41.00
41.18
Short-Circuit Current
I
sc
A
10.72
10.78
10.86
10.92
10.97
Rated Voltage
V
mp
V
32.85
33.03
33.20
33.37
33.52
Rated Current
I
mp
A
10.05
10.14
10.24
10.34
10.44
Fuse rating
A
20
20
20
20
20
Max. System Voltage
V
1,000
1,000
1,000
1,000
1,000
TABLE 5: ELECTRICAL RATINGS OF MSE PERC 66 (6BB, BLACK BACKSHEET) MODULE SERIES
Parameters
MSE375SX5R
MSE380SX5R
MSE385SX5R
MSE390SX5R
Power Output
P
max
Wp
375
380
385
390
Tolerance
%
-0/+3 %
-0/+3 %
-0/+3 %
-0/+3 %
Open Circuit Voltage V
oc
V
44.64
44.84
45.03
45.17
Short-Circuit Current
I
sc
A
10.85
10.91
10.97
11.01
Rated Voltage
V
mp
V
36.56
36.75
36.93
37.06
Rated Current
I
mp
A
10.26
10.34
10.42
10.52
Fuse rating
A
20
20
20
20
Max. System Voltage
V
1,000
1,000
1,000
1,000
TABLE 6: MODULE TEMPERATURE COEFFICIENT
Module
Peak power: δ %/°C)
Voltage: Β (%/°C)
Current: α (%/°C)
NOCT (°C)
MSExxxSX6S / MSExxxSX6W
(
xxx=405-425, in step of 5W, xxx is standing
for rated output power at STC
)
-0.359% /
o
C
-0.261% /
o
C
0.044% /
o
C
44.69
o
C
MSExxxSX6Z
(
xxx=405-425, in step of 5W, xxx is standing
for rated output power at STC
)
-0.361% /
o
C
-0.262% /
o
C
0.039% /
o
C
44.43
o
C
MSExxxSX5T
(
xxx=330-345, in step of 5W, xxx is standing
for rated output power at STC
)
-0.361% /
o
C
-0.262% /
o
C
0.039% /
o
C
44.43
o
C
MSExxxSX5K
(
xxx=335-350, in step of 5W, xxx is standing
for rated output power at STC
)
-0.361% /
o
C
-0.262% /
o
C
0.049% /
o
C
45.86
o
C
MSExxxSX5R
(
xxx=375-390, in step of 5W, xxx is standing
for rated output power at STC
)
-0.361% /
o
C
-0.262% /
o
C
0.039% /
o
C
44.43
o
C
9.0
MECHANICAL INSTALLATION
Mission Solar PV modules are considered to be in compliance with UL 61730 only when mounted in the manner specified
by the mounting options below. Per UL standards, the maximum number of modules connected in series/parallel with
correction factor of 1.56 as specified in the NEC is as follows:
a.
19/1
for 60- cell module with maximum system voltage of 1000V
b.
24/1
for 72-cell module with maximum system voltage of 1500V
•
Please refer to your local Authority Having Jurisdiction (AHJ) as well as best installation practices for the
maximum number of modules that can be installed in series and in parallel for your specific installation project
site and application.
•
For proper guidelines on tilt or elevation angle for your installation, please refer to the standard PV installation
guide from a reputable installer or systems integrator.