background image

Page 21

 

 

Ingenio® EZporator® Electroporation System

 

Product User Manual

 

| Instructions for MIR 51000

 

Warranty

 

General Warranty

 

The Ingenio® EZporator® Electroporation System is warrantied for one year from the 
date of purchase. At its discretion, Mirus Bio will repair or replace the unit if it is 
found to be defective as to workmanship or materials. This warranty is considered 
void for any instrument which has been: 

 

1. Subjected to misuse, neglect, accident or abuse 

 

2. Repaired or altered by anyone other than Mirus Bio without express and prior  

approval

 

3. Used in violation of instructions furnished by Mirus Bio

 

4. Changed in any way from its original factory design

 

5. Used with parts, connections or electrodes not manufactured by Mirus Bio

 

 

This warranty extends only to the original purchaser. MIRUS BIO IS NOT LIABLE FOR 
INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some territories do not allow exclusion 
or limitation of incidental or consequential damages so the above limitation or ex-
clusion may not apply to you. THERE ARE NO IMPLIED WARRANTIES OF MERCHANT-
ABILITY, OR FITNESS FOR A PARTICULAR USE, OR OF ANY OTHER NATURE. Some 
territories do not allow this limitation on an implied warranty, so the above limita-
tion may not apply to you. Without limiting the generality of the foregoing, Mirus 
Bio shall not be liable for any claims of any kind whatsoever, as to the equipment 
delivered or for non

-

delivery of equipment and whether or not based on negligence. 

 

FOR U.S. CUSTOMERS: If a defect arises within the warranty period, promptly con-
tact Mirus Bio LLC, 5602 Research Park Blvd., Ste. 210, Madison, Wisconsin, 53719 
using our toll free number 888.530.0801 (U.S. Only) or +1

-

608.441.2852. E

-

mail: 

[email protected]. Goods will not be accepted for return unless a Re-
turned Materials Authorization (RMA) number has been issued by our customer 
service department. The customer may be responsible for shipping charges. Please 
allow a reasonable period of time for completion of repairs, replacement and re-
turn. If the unit is replaced, the replacement unit is covered only for the remainder 
of the original warranty period dating from the purchase of the original device or for 
90 days, whichever is longer. EZporator® Electroporation System serial numbers are 
found on the stickers applied to the outer shipping box and on the bottom of the 
EZporator® Pulse Generator. 

 

FOR CUSTOMERS OUTSIDE THE U.S.: Please contact your official Mirus Bio EZpora-
tor® Electroporation System distributor immediately to address any defects that 
arise within the warranty period.

 

Mirus Bio 

LLC

 

www.mirusbio.com

 │ 

[email protected]

 │ 

U.S. Toll Free: 844.MIRUSBIO 

(844.647.8724)│ 

Direct: +1.608.441.2852

 

Содержание Ingenio EZporator MTR 51000

Страница 1: ...Ingenio EZporator Electroporation System Product User Manual MIR 51000 RevB 121520 mirusbio com...

Страница 2: ...ob Pulse Button 10 EZporator System Protocols Quick Reference Guidelines 11 Instructions for Use with Ingenio Solution and Kits 12 13 Optimization Cell Density and Passage Number 14 Nucleic Acid Purit...

Страница 3: ...ection efficiency Optimizing parameters such as nucleic acid amount cell density and voltage for each cell type will improve transfection efficiency and decrease cell mortality thus making electropora...

Страница 4: ...F capacitance High Voltage HV mode Voltage range of 30 to 2 500 V with 10 V resolution 150 internal resistance and 36 F capacitance Streamlined experimental approach 1 Initialize instrument 2 Set vol...

Страница 5: ...rking environments Altitude 2 000 m above sea level operating Mechanical Characteristics Maximum Voltage Output 2 500 V peak Maximum Pulse Length 125 ms at 400 V peak or 5 ms at 2 500 V peak Pulse Wav...

Страница 6: ...llow 3 to 5 cm of clearance on all sides of the module for proper cooling GROUND THE PRODUCT This product is grounded through the grounding con ductor of the power cord To avoid electric shock the gro...

Страница 7: ...d by Mirus Bio authorized personnel only If there are any questions about the operation of this instrument call Mirus Bio Technical Support at 888 530 0801 or 1 608 441 2852 Caution Notice This symbol...

Страница 8: ...insert the power cord plug into an appropriate electrical outlet i e 110 240 VAC To connect the EZporator Cuvette Chamber to the Pulse Generator insert the color coded plugs attached to the Cuvette C...

Страница 9: ...0 V 2 V increments 1050 F capacitance HV mode from 20 to 2500 V 10 V increments 6 F capacitance Initializing and Charging Initializing and charging capacitor to the preset voltage level Pulsing Delive...

Страница 10: ...separate voltage mode switch Use the Voltage Adjust knob to adjust the voltage from 20 to 400 V in LV mode in 2 V increments and from 30 to 2 500 V in HV mode in 10 V increments If in LV mode increasi...

Страница 11: ...fy that the EZporator is in READY mode Then use the Voltage Adjust knob to dial in the appropriate voltage and mode LV or HV for the cell type and buffer to be electroporated NOTE LV mode is used for...

Страница 12: ...ypsin EDTA if applicable and complete growth medium to room temperature 2 Harvest and count cells to determine cell density cells ml 3 Determine the total electroporation volume required to perform th...

Страница 13: ...t room temperature NOTE The optimal pulse conditions or program settings will vary depending on the cell type and electroporator used For most mammalian and insect cell types optimal conditions fall w...

Страница 14: ...s typically between 1 10 106 cells ml Higher cell densities are typically recommended for suspension cells e g 1 x 107 cells ml whereas the recommended range for adherent cells is 1 5 106 cells ml Cel...

Страница 15: ...cuvettes Time Constant Time constant TC values will vary depending on electro poration buffer conductivity volume in the cuvette cell density and tempera ture Typical TC values with Ingenio Electropo...

Страница 16: ...0 250 150 280 COS 7 0 2 0 4 5 2 5 100 250 150 260 HEK 293 0 2 0 4 5 2 5 100 250 160 250 HEK 293T 0 2 0 4 5 5 250 250 HeLa 0 2 0 4 3 2 5 100 250 130 260 Hepa 0 2 0 4 5 2 100 160 HepG2 0 2 0 4 5 2 5 100...

Страница 17: ...or is adequately rated If the message persists contact Mirus Technical Support Setpoint too low The user has entered a setpoint that is outside of normal operating specifications Increase the voltage...

Страница 18: ...e If you do not observe expression of your target insert verify the se quence of the plasmid DNA Proper experimental controls were not included for plasmid delivery To verify efficient electroporation...

Страница 19: ...ctroporation mix Reduce the amount of DNA used for electroporation DNA concentrations as low as 5 g ml of the final electroporation volume can be used Compare toxicity levels against a cells Ingenio E...

Страница 20: ...EZporator fuse is located at the back of the instrument offset below the green Power Button see below Blown fuses can easily be replaced by following these instructions 1 Power off the Pulse Generato...

Страница 21: ...you Without limiting the generality of the foregoing Mirus Bio shall not be liable for any claims of any kind whatsoever as to the equipment delivered or for non delivery of equipment and whether or n...

Страница 22: ...pent and materials used will be supplied Shipment of your EZporator Device to Mirus Bio should be prepaid Your bill will include return shipment freight charg es Disassembly by the user is prohibited...

Страница 23: ...MIR 51000 Notes Mirus Bio LLC www mirusbio com techsupport mirusbio com U S Toll Free 844 MIRUSBIO 844 647 8724 Direct 1 608 441 2852 1996 2021 All rights reserved Mirus Bio LLC All trademarks are th...

Страница 24: ...Mirus Bio LLC 5602 Research Park Blvd Ste 210 Madison WI 53719 USA U S Toll free 888 530 0801 Direct 1 608 441 2852 5423 027 R2 0...

Отзывы: