Ingenio® EZporator® Electroporation System

 

Product User Manual

 

| Instructions for MIR 51000

 

Technology Overview

 

 

Electroporation is a physical transfection method that utilizes short electrical pulses 
to create transient membrane pores in cells through which small particles (e.g. DNA, 
RNA, proteins, etc.) can pass. Optimal electroporator pulse settings and composition 
of cell resuspension solution greatly enhance electro

-

permeabilization and promote 

passage of particles through the cell membrane. Since electroporation is an effective 
transfection method regardless of the type of molecule delivered or the target cells, 
this technique provides a robust and universal approach for multiple applications, 
including gene expression, RNAi, stable cell line generation and CRISPR/Cas genome 
editing.

 

 

Electroporation is an invaluable alternative for cell types that are not responsive to 
chemical transfection and often yields significantly higher transfection efficiency. 
Optimizing parameters such as nucleic acid amount, cell density and voltage for 
each cell type will improve transfection efficiency and decrease cell mortality, thus 
making electroporation suitable for transfecting various cell types with any type of 
nucleic acid or small molecule.

 

 

The Ingenio® EZporator® Electroporation System was developed with both efficiency 
and simplicity for the researcher in mind. This system utilizes an 

exponential decay 

pulse

* to effectively deliver cargo to cells in a cuvette with the push of a button. The 

Ingenio® EZporator® was designed for use with Ingenio® Electroporation Kits and 
Solution. Use of electroporation solutions not manufactured by Mirus Bio may result 
in low transfection efficiency and high cellular cytotoxicity. Additionally, use of in-
compatible electroporation solutions may cause damage to the instrument and will 
void the warranty. More information on Ingenio® Electroporation Solution and Kits 
is available at 

mirusbio.com/ingenio

.  

 

 

*In exponential

-

decay pulse conditions, a set voltage is released from the capacitor and decays 

exponentially. See Optimization Section (page 14) for additional details.

 

Ingenio® EZporator® Electroporation System and Ingenio® 

Electroporation Solution, cuvettes and cell droppers.

 

Содержание Ingenio EZporator MTR 51000

Страница 1: ...Ingenio EZporator Electroporation System Product User Manual MIR 51000 RevB 121520 mirusbio com...

Страница 2: ...ob Pulse Button 10 EZporator System Protocols Quick Reference Guidelines 11 Instructions for Use with Ingenio Solution and Kits 12 13 Optimization Cell Density and Passage Number 14 Nucleic Acid Purit...

Страница 3: ...ection efficiency Optimizing parameters such as nucleic acid amount cell density and voltage for each cell type will improve transfection efficiency and decrease cell mortality thus making electropora...

Страница 4: ...F capacitance High Voltage HV mode Voltage range of 30 to 2 500 V with 10 V resolution 150 internal resistance and 36 F capacitance Streamlined experimental approach 1 Initialize instrument 2 Set vol...

Страница 5: ...rking environments Altitude 2 000 m above sea level operating Mechanical Characteristics Maximum Voltage Output 2 500 V peak Maximum Pulse Length 125 ms at 400 V peak or 5 ms at 2 500 V peak Pulse Wav...

Страница 6: ...llow 3 to 5 cm of clearance on all sides of the module for proper cooling GROUND THE PRODUCT This product is grounded through the grounding con ductor of the power cord To avoid electric shock the gro...

Страница 7: ...d by Mirus Bio authorized personnel only If there are any questions about the operation of this instrument call Mirus Bio Technical Support at 888 530 0801 or 1 608 441 2852 Caution Notice This symbol...

Страница 8: ...insert the power cord plug into an appropriate electrical outlet i e 110 240 VAC To connect the EZporator Cuvette Chamber to the Pulse Generator insert the color coded plugs attached to the Cuvette C...

Страница 9: ...0 V 2 V increments 1050 F capacitance HV mode from 20 to 2500 V 10 V increments 6 F capacitance Initializing and Charging Initializing and charging capacitor to the preset voltage level Pulsing Delive...

Страница 10: ...separate voltage mode switch Use the Voltage Adjust knob to adjust the voltage from 20 to 400 V in LV mode in 2 V increments and from 30 to 2 500 V in HV mode in 10 V increments If in LV mode increasi...

Страница 11: ...fy that the EZporator is in READY mode Then use the Voltage Adjust knob to dial in the appropriate voltage and mode LV or HV for the cell type and buffer to be electroporated NOTE LV mode is used for...

Страница 12: ...ypsin EDTA if applicable and complete growth medium to room temperature 2 Harvest and count cells to determine cell density cells ml 3 Determine the total electroporation volume required to perform th...

Страница 13: ...t room temperature NOTE The optimal pulse conditions or program settings will vary depending on the cell type and electroporator used For most mammalian and insect cell types optimal conditions fall w...

Страница 14: ...s typically between 1 10 106 cells ml Higher cell densities are typically recommended for suspension cells e g 1 x 107 cells ml whereas the recommended range for adherent cells is 1 5 106 cells ml Cel...

Страница 15: ...cuvettes Time Constant Time constant TC values will vary depending on electro poration buffer conductivity volume in the cuvette cell density and tempera ture Typical TC values with Ingenio Electropo...

Страница 16: ...0 250 150 280 COS 7 0 2 0 4 5 2 5 100 250 150 260 HEK 293 0 2 0 4 5 2 5 100 250 160 250 HEK 293T 0 2 0 4 5 5 250 250 HeLa 0 2 0 4 3 2 5 100 250 130 260 Hepa 0 2 0 4 5 2 100 160 HepG2 0 2 0 4 5 2 5 100...

Страница 17: ...or is adequately rated If the message persists contact Mirus Technical Support Setpoint too low The user has entered a setpoint that is outside of normal operating specifications Increase the voltage...

Страница 18: ...e If you do not observe expression of your target insert verify the se quence of the plasmid DNA Proper experimental controls were not included for plasmid delivery To verify efficient electroporation...

Страница 19: ...ctroporation mix Reduce the amount of DNA used for electroporation DNA concentrations as low as 5 g ml of the final electroporation volume can be used Compare toxicity levels against a cells Ingenio E...

Страница 20: ...EZporator fuse is located at the back of the instrument offset below the green Power Button see below Blown fuses can easily be replaced by following these instructions 1 Power off the Pulse Generato...

Страница 21: ...you Without limiting the generality of the foregoing Mirus Bio shall not be liable for any claims of any kind whatsoever as to the equipment delivered or for non delivery of equipment and whether or n...

Страница 22: ...pent and materials used will be supplied Shipment of your EZporator Device to Mirus Bio should be prepaid Your bill will include return shipment freight charg es Disassembly by the user is prohibited...

Страница 23: ...MIR 51000 Notes Mirus Bio LLC www mirusbio com techsupport mirusbio com U S Toll Free 844 MIRUSBIO 844 647 8724 Direct 1 608 441 2852 1996 2021 All rights reserved Mirus Bio LLC All trademarks are th...

Страница 24: ...Mirus Bio LLC 5602 Research Park Blvd Ste 210 Madison WI 53719 USA U S Toll free 888 530 0801 Direct 1 608 441 2852 5423 027 R2 0...

Отзывы: