GUIDE TO INSTALLATION AND OPERATION
HMP-1801 |
35
3.4.12 The Alarm Config panel
This panel allows the alarm reporting
of the HMP-1801 to be configured.
The panel opens in a new window
when the button is clicked, and can be
resized if needed.
The panel is organized in columns.
Status/Name
This contains an expandable tree listing all the alarms reported by this HMP-1801 card.
•
Each alarm name includes an icon that shows its current status
The
Card LED
,
Overall alarm
and
GSM contribution
columns contain pulldown lists that allow the level of
contribution of each individual alarm to the alarm named in the column heading to be set.
•
If there is no arrowhead in the box, there is no pulldown and the alarm is not user-configurable
CARD LED
This column allows configuration of the behavior of the HMP-1801’s card-edge Status LED.
Overall Alarm
This column allows configuration of the contribution of each individual alarm to the Overall Alarm associated with
this card. The Overall Alarm is shown in the upper left corner of the iControl panel, and also appears at the bottom
of the Status/Name column.
GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated
with this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external
applications. The possible values for this contribution are related to the Overall alarm contribution:
Figure 3.32 Alarm Configuration Panel