Mira vigour Скачать руководство пользователя страница 5

4

10.

  Turn off the electrical and water supplies before removing the cover. The electricity 

must  be  turned  off  at  the  mains  and,  if  applicable,  the  appropriate  circuit  fuse 
removed.

11.

  Mains connections are exposed when the cover is removed.

12.

  Moving parts are exposed when the cover is removed.

13.

  Isolate the electricity and water supplies and refer to “

To contact us

”, on the back 

page of this guide, if any of the following conditions occur:

The cover is not correctly itted and water has entered the case

• 

The case is damaged

• 

The Appliance begins to make an odd noise, smell or smoke

• 

The Appliance  shows  signs  of  a  distinct  change  in  performance,  indicating  a 

• 

need for maintenance

The Appliance is frozen

• 

14. 

Make sure all electrical connections are tight, to prevent overheating.

Caution!

1.

 

Read all of these instructions and retain this guide for later use

.

2.

 

Pass on this guide in the event of change of ownership of the installation site.

3.

 

Follow all warnings, cautions and instructions contained in this guide.

4.

 

Follow  all  warnings,  cautions  and  instructions  contained  on  or  inside  the 
appliance.

5

The  electrical  installation  must  comply  with  the  “Requirements  for  Electrical 
Installations” commonly referred to as the IEE Wiring Regulations, or any particular 

regulations and practices speciied by the local electricity supply company, in force 

at the time of installation. The installation should be carried out by an electrician or 
contractor who is registered with, or is a member of an association such as:

National Inspection Council for Electrical Installation and Contracting (NICEIC), 

• 

throughout the UK

The Electrical Contractors Association (ECA), England and Wales

• 

The Electrical Contractors Association of Scotland (ECAS)

• 

6.

 

The  plumbing  installation  must  comply  with  Water  Supply  Regulations/Bye-laws 

(Scotland), Building Regulations or any particular regulations and practices, speciied 

by the local water company or water undertakers. The installation should be carried 

out by a plumber or contractor who is registered with, or is a member of an association 
such as:

Institute of Plumbing (IOP), throughout the UK

• 

National Association of Plumbing, Heating and Mechanical Services Contractors 

• 

(NAPH & MSC), England and Wales

Scottish  and  Northern  Ireland  Plumbing  Employers’  Federation  (SNIPEF), 

• 

Scotland and Northern Ireland

7.

  Anyone  who  may  have  dificulty  understanding  or  operating  the  controls  of  any 

shower  should  be  attended  whilst  showering.  Particular  consideration  should  be 

given to the young, the elderly, the inirm, or anyone inexperienced in the correct 

operation of the controls.

8.

 

When the Appliance has reached the end of its serviceable life, it should be disposed 
of in a safe manner, in accordance with current local authority recycling, or waste 
disposal policy.

Содержание vigour

Страница 1: ...1 POWER SHOWER These instructions are to be left with the user T h e r m o s t a t i c THERMOSTATIC Installation and User Guide...

Страница 2: ...st with low interest rates PRICE MATCH always get the best deals available Boilers Radiators Heating controls Pipes ittings Cylinders Fires Renewable energy Bathroom suites Kitchen sinks taps Showers...

Страница 3: ...on Requirements 8 Installation 9 General 9 Electrical 9 Plumbing 10 Commissioning 17 Maximum Temperature Setting 18 Disabling the Temperature Override Button 20 Operation 21 Fault Diagnosis 22 Fault D...

Страница 4: ...MAKE SURE SUPPLEMENTARY BONDING COMPLIES WITH THE REQUIREMENTS FOR ELECTRICAL INSTALLATIONS In accordance with the current edition of The Plugs and Sockets etc Safety Regulations in force at the time...

Страница 5: ...ces speciied by the local electricity supply company in force at the time of installation The installation should be carried out by an electrician or contractor who is registered with or is a member o...

Страница 6: ...trol Knob 1 x Temperature Indicator Trim 3 x Rubber Feet 1 x Push Fit Release Tool 3 x Rubber Wall Plugs 3 x Fixing Screws Tick the appropriate boxes to familiarise yourself with the part names and to...

Страница 7: ...6 DIMENSIONS All dimensions are nominal and in millimetres 310 66 28 210 28 20 20 130 80 88...

Страница 8: ...in 1 C of selected temperature with a 10 C change in the hot or cold water supply If the cold supply fails the thermostatic mixer will shut down low of water to seepage levels in approximately 2 secon...

Страница 9: ...8 Gravity Fed system The shower MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressure INSTALLATION REQUIREMENTS 10 m Maximum 80 mm Minimum 30 60...

Страница 10: ...hower unit is designed for surface mounting only and must not be recessed into any wall or cavity or tiled up to as this prevents air circulating to the rear of the unit Electrical 1 The shower unit m...

Страница 11: ...nsfer may damage plastic components 5 Do not use jointing compounds on the shower unit joints they may cause damage to the mechanism inside 6 Do not insert ingers into the push it connections 7 The su...

Страница 12: ...ition on the slide bar the handset does not fall below the minimum clearance gap between the bath or shower tray spillover level of 25 mm 2 Hot and cold inlet supply connections are Hot Left Cold Righ...

Страница 13: ...trunking not supplied Allow suficient cable to connect to the terminal block approximately 275 mm Strip back approximately 30 mm of outer cable insulation 5 Loosen the three cover securing screws and...

Страница 14: ...structures 9 Use the push it release tool to push the grey collars into the manifold to release the shower unit from the supply pipes Warning Make sure there are no buried cables or pipes near the ix...

Страница 15: ...e of the unit 13 Fit the blanking plates to the unit case in the following manner For Top Inlet Pipework For Rear Inlet Pipework For Bottom Inlet Pipework Rubber Feet Fit the full blanking plates to t...

Страница 16: ...pplied or alternative ixings depending on the wall structure Do not over tighten Make sure that the electrical supply cable is correctly seated in the channel in the back of the case 17 Connect the li...

Страница 17: ...21 Insert the temperature indicator trim and the inner temperature control knob 22 The power thermostatic shower will now require commissioning refer to COMMISSIONING 23 Install the shower ittings ref...

Страница 18: ...eaks 3 Switch on the electrical supply 4 Turn the outer flow control anticlockwise to full low 5 Rotate the inner temperature control anticlockwise to check the hot supply and clockwise to check the c...

Страница 19: ...ture stop Do not depress the override button 3 Check the shower temperature 4 If the maximum temperature requires adjustment then remove the outer low control and the inner temperature control knobs S...

Страница 20: ...h the retaining screw 8 Insert the outer low control knob in the maximum low position 9 Insert the temperature indicator trim and the inner temperature control knob Caution If resistance is felt when...

Страница 21: ...h it release tool under the outer low control knob and lever the control knob assembly off the shower unit 3 Unclip the concealed end of the override button from the temperature indicator trim and car...

Страница 22: ...for warmer water and clockwise for cooler water the numbers indicate the relative temperature 1 cold 4 tepid 7 Hot Warning Operation of the override button will allow a shower temperature above the p...

Страница 23: ...ater temperatures do not exceed 65 C Reset maximum temperature refer to COMMISSIONING Blend temperature unstable Spray plate blocked Inlet ilters blocked Isolating valve partially closed Plumbing syst...

Страница 24: ...is too high up the pipe Refer to the plumbing system diagram in the INSTALLATION REQUIREMENTS for the correct connection method Note the 1 metre hot takeoff dimension Consider increasing the cold fee...

Страница 25: ...ssembly The pump does not operate Electrical supply failure PCB failure Potentiometer failure Motor overheated thermal switch operated Check the power supply Renew the PCB Renew the harness assembly I...

Страница 26: ...ore replacing any parts make sure that the underlying cause of the malfunction has been resolved Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for c...

Страница 27: ...mponents identiied C 453 13 Solenoid Valve Assembly components identiied D 453 14 Filter Cap Assembly 453 15 Seal Pack components identiied E 453 22 Stud Wall Fixing Kit Push it Release Tool 3 x Fixin...

Страница 28: ...27 147 67 453 01 453 14 A B H A D E D E B D 1532 332 453 28 A F A E G E B E F E C C G H G H G 453 08 1532 365...

Страница 29: ...ogramme calls may be recorded or monitored Our Customer Services Team is comprehensively trained to provide every assistance you may need help and advice spare parts or a service visit Spare Parts We...