Maximum Temperature Setting
It may be necessary to adjust the maximum temperature for site conditions to make
sure of safe showering from the unit. Make sure that the hot water temperature is at
least 12 °C above the required temperature for correct operation of the thermostatic
power shower.
To reset the maximum outlet temperature follow the sequence below :
1.
T u r n t h e o u t e r f l o w c o n t r o l
anticlockwise
to maximum low.
2.
Turn the inner temperature control
knob
anticlockwise
to the maximum
temperature stop.
Do not depress
the override button
.
3.
Check the shower temperature.
4.
If the maximum temperature requires
adjustment then remove the outer
low control and the inner temperature
control knobs. Slide the end of the
push-it release tool under the outer
flow control, lever the outer flow
control and the inner temperature
control knobs off together from the
shower unit.
5.
Remove the small label covering the
retaining screw on the temperature
hub. Unscrew the retaining screw and
remove the temperature hub.
Note!
This will void the factory
setting.
Outer Flow Control
Maximum
Flow Position
Temperature Hub
Retaining Screw
Temperature
Hub
Inner Temperature Control Knob
Maximum Temperature Position