Mira vigour Скачать руководство пользователя страница 29

28

CUSTOMER SERVICE

© Kohler Mira Limited, October 2007

1088849-W2-A   (B85N)

Guarantee of Quality

Mira Showers guarantee your product against any defect 
in  materials  or  workmanship  for  the  period  shown  in  the 
Guarantee  Registration  Document  included  with  your 
shower.
Alternatively,  to  confi rm  the  applicable  guarantee  period 
please contact Customer Services.
To  validate  the  guarantee,  please  return  your  completed 
registration card.
Within the guarantee period we will resolve defects, free 
of  charge,  by  repairing  or  replacing  parts  or  modules  as 
we may choose.
To be free of charge, service work must only be undertaken 
by Mira Showers or our approved agents.
Service  under  this  guarantee  does  not  affect  the  expiry 
date.
The  guarantee  on  any  exchanged  parts  or  product  ends 
when the normal product guarantee period expires.

Not covered by this guarantee:

Damage  or  defects  arising  from  incorrect  installation, 
improper  use  or  lack  of  maintenance,  including  build-up 
of limescale.
Damage or defects if the product is taken apart, repaired or 
modifi ed by any persons not authorised by Mira Showers 
or our approved agents.
This  guarantee  is  in  addition  to  your  statutory  and  other 
legal rights.

What to do if something goes wrong

If  when  you  first  use  your  shower,  it  doesn’t  function 
correctly, fi rst contact your installer to check that installation 
and commissioning are satisfactory and in accordance with 
the instructions in this manual. We are on hand to offer you 
or your installer any advice you may need.
Should  this  not  resolve  the  diffi culty,  simply  contact  our 
Customer  Services Team  who  will  give  every  assistance 
and,  if  necessary,  arrange  for  our  service  engineer  to 
visit. If the performance of your shower declines, consult 
this manual to see whether simple home maintenance is 
required. Please call our Customer Services Team to talk 
the  diffi culty  through,  request  a  service  under  guarantee 
if  applicable,  or  take  advantage  of  our  comprehensive 
After-Sales service.
As part of our quality and training programme calls may be 
recorded or monitored.
Our Customer Services Team is comprehensively trained to 
provide every assistance you may need: help and advice, 
spare parts or a service visit.

Spare Parts

We maintain an extensive stock of spares and aim to provide 
support throughout the product’s expected life.
Spares  can  be  purchased  from  approved  stockists  or 
merchants (locations on request) or direct from Customer 
Services.
Spares direct will normally be despatched within two working 
days. Payment can be made by Visa or MasterCard at the 
time of ordering. Should payment by cheque be preferred, 
a pro-forma invoice will be sent.
All  spares  are  guaranteed  for  12  months  from  date  of 
purchase. Spares that have been supplied directly from us 
can be returned within one month from date of purchase, 
providing  that  they  are  in  good  order  and  the  packaging 
is unopened.

Note!

 Returned spares will be subject to a 15% restocking 

charge and authorisation must be obtained before return. 
Please contact our Customer Services Team.

Note! 

In the interests of safety, spares requiring exposure 

to mains voltages can only be sent to competent persons.

Service

Our Service Force is available to provide a quality service 
at a reasonable cost. You will have the assurance of a Mira 
trained  engineer/agent,  genuine  Mira  spare  parts  and  a 
12 month guarantee on the repair.
Payment  should  be  made  directly  to  the  engineer/agent 
using  Visa,  MasterCard  or  a  cheque  supported  by  a 
banker’s card.

To Contact Us

England, Scotland, Wales and Northern Ireland
Mira Showers Customer Services

Telephone: 0870 241 0888, Mon to Fri 8:00 am - 5:30 pm
 

 

Sat 8:30 am - 3:30 pm

E-mail: 

[email protected]

Fax: 

01242 282595

By Post: 

Cromwell Road, Cheltenham,

 

Gloucestershire, GL52 5EP

Eire
Modern Plant Ltd (Dublin)

Telephone: 01 459 1344, 

Mon to Fri 9:00 am - 5:00 pm

E-mail: 

[email protected]

Fax: 

Dublin 01 459 2329

Post: 

Otter House, Naas Road,

 

Clondalkin, Dublin 22

Modern Plant (Cork)

Telephone: 021 496 8755,  Mon to Fri 9:00 am - 5:00 pm
E-mail: 

[email protected]

Fax: 

021 496 8607

Post: 

Tramore Road, Cork

Mira is a registered trade mark of 

Kohler Mira Limited.

The company reserves the right to alter 

product specifi cations without notice.

www.mirashowers.com

Содержание vigour

Страница 1: ...1 POWER SHOWER These instructions are to be left with the user T h e r m o s t a t i c THERMOSTATIC Installation and User Guide...

Страница 2: ...st with low interest rates PRICE MATCH always get the best deals available Boilers Radiators Heating controls Pipes ittings Cylinders Fires Renewable energy Bathroom suites Kitchen sinks taps Showers...

Страница 3: ...on Requirements 8 Installation 9 General 9 Electrical 9 Plumbing 10 Commissioning 17 Maximum Temperature Setting 18 Disabling the Temperature Override Button 20 Operation 21 Fault Diagnosis 22 Fault D...

Страница 4: ...MAKE SURE SUPPLEMENTARY BONDING COMPLIES WITH THE REQUIREMENTS FOR ELECTRICAL INSTALLATIONS In accordance with the current edition of The Plugs and Sockets etc Safety Regulations in force at the time...

Страница 5: ...ces speciied by the local electricity supply company in force at the time of installation The installation should be carried out by an electrician or contractor who is registered with or is a member o...

Страница 6: ...trol Knob 1 x Temperature Indicator Trim 3 x Rubber Feet 1 x Push Fit Release Tool 3 x Rubber Wall Plugs 3 x Fixing Screws Tick the appropriate boxes to familiarise yourself with the part names and to...

Страница 7: ...6 DIMENSIONS All dimensions are nominal and in millimetres 310 66 28 210 28 20 20 130 80 88...

Страница 8: ...in 1 C of selected temperature with a 10 C change in the hot or cold water supply If the cold supply fails the thermostatic mixer will shut down low of water to seepage levels in approximately 2 secon...

Страница 9: ...8 Gravity Fed system The shower MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressure INSTALLATION REQUIREMENTS 10 m Maximum 80 mm Minimum 30 60...

Страница 10: ...hower unit is designed for surface mounting only and must not be recessed into any wall or cavity or tiled up to as this prevents air circulating to the rear of the unit Electrical 1 The shower unit m...

Страница 11: ...nsfer may damage plastic components 5 Do not use jointing compounds on the shower unit joints they may cause damage to the mechanism inside 6 Do not insert ingers into the push it connections 7 The su...

Страница 12: ...ition on the slide bar the handset does not fall below the minimum clearance gap between the bath or shower tray spillover level of 25 mm 2 Hot and cold inlet supply connections are Hot Left Cold Righ...

Страница 13: ...trunking not supplied Allow suficient cable to connect to the terminal block approximately 275 mm Strip back approximately 30 mm of outer cable insulation 5 Loosen the three cover securing screws and...

Страница 14: ...structures 9 Use the push it release tool to push the grey collars into the manifold to release the shower unit from the supply pipes Warning Make sure there are no buried cables or pipes near the ix...

Страница 15: ...e of the unit 13 Fit the blanking plates to the unit case in the following manner For Top Inlet Pipework For Rear Inlet Pipework For Bottom Inlet Pipework Rubber Feet Fit the full blanking plates to t...

Страница 16: ...pplied or alternative ixings depending on the wall structure Do not over tighten Make sure that the electrical supply cable is correctly seated in the channel in the back of the case 17 Connect the li...

Страница 17: ...21 Insert the temperature indicator trim and the inner temperature control knob 22 The power thermostatic shower will now require commissioning refer to COMMISSIONING 23 Install the shower ittings ref...

Страница 18: ...eaks 3 Switch on the electrical supply 4 Turn the outer flow control anticlockwise to full low 5 Rotate the inner temperature control anticlockwise to check the hot supply and clockwise to check the c...

Страница 19: ...ture stop Do not depress the override button 3 Check the shower temperature 4 If the maximum temperature requires adjustment then remove the outer low control and the inner temperature control knobs S...

Страница 20: ...h the retaining screw 8 Insert the outer low control knob in the maximum low position 9 Insert the temperature indicator trim and the inner temperature control knob Caution If resistance is felt when...

Страница 21: ...h it release tool under the outer low control knob and lever the control knob assembly off the shower unit 3 Unclip the concealed end of the override button from the temperature indicator trim and car...

Страница 22: ...for warmer water and clockwise for cooler water the numbers indicate the relative temperature 1 cold 4 tepid 7 Hot Warning Operation of the override button will allow a shower temperature above the p...

Страница 23: ...ater temperatures do not exceed 65 C Reset maximum temperature refer to COMMISSIONING Blend temperature unstable Spray plate blocked Inlet ilters blocked Isolating valve partially closed Plumbing syst...

Страница 24: ...is too high up the pipe Refer to the plumbing system diagram in the INSTALLATION REQUIREMENTS for the correct connection method Note the 1 metre hot takeoff dimension Consider increasing the cold fee...

Страница 25: ...ssembly The pump does not operate Electrical supply failure PCB failure Potentiometer failure Motor overheated thermal switch operated Check the power supply Renew the PCB Renew the harness assembly I...

Страница 26: ...ore replacing any parts make sure that the underlying cause of the malfunction has been resolved Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for c...

Страница 27: ...mponents identiied C 453 13 Solenoid Valve Assembly components identiied D 453 14 Filter Cap Assembly 453 15 Seal Pack components identiied E 453 22 Stud Wall Fixing Kit Push it Release Tool 3 x Fixin...

Страница 28: ...27 147 67 453 01 453 14 A B H A D E D E B D 1532 332 453 28 A F A E G E B E F E C C G H G H G 453 08 1532 365...

Страница 29: ...ogramme calls may be recorded or monitored Our Customer Services Team is comprehensively trained to provide every assistance you may need help and advice spare parts or a service visit Spare Parts We...