Disabling the Temperature Override Button

The temperature override button allows the user to override the preset maximum 
temperature. The temperature override button should be disabled if the power shower 

is to be used by the young, the elderly, the inirm, or anyone inexperienced in the 

correct operation of the controls.
Follow the instructions below to disable the temperature override button:

1.

  Turn  the  outer  flow  control  knob 

clockwise

  to  the  off  position  and 

the  inner  temperature  control  knob 

clockwise

 to full cold.

2.

  Slide the end of the push-it release 

tool under the outer low control knob 

and lever the control knob assembly 

off the shower unit.

3.

  Unclip  the  concealed  end  of  the 

override button from the temperature 
indicator trim and carefully remove the 
override button.

4. 

Rotate  the  override  button  through 

half a turn (180°) and reit. Make sure 

the override button is lush with the 

temperature indicator trim.

5.

  Insert the outer low control knob in 

the off position.

6.

  Insert the temperature indicator trim 

and  the  inner  temperature  control 

knob. Make sure the inner temperature 

control knob is pushed fully onto the 

temperature hub.

7.

  The  temperature  override  button  is 

now disabled.

Inner Temperature 

Control Knob

Temperature Indicator Trim

Override Button

Full Cold Position

Off Position

Содержание vigour

Страница 1: ...1 POWER SHOWER These instructions are to be left with the user T h e r m o s t a t i c THERMOSTATIC Installation and User Guide...

Страница 2: ...st with low interest rates PRICE MATCH always get the best deals available Boilers Radiators Heating controls Pipes ittings Cylinders Fires Renewable energy Bathroom suites Kitchen sinks taps Showers...

Страница 3: ...on Requirements 8 Installation 9 General 9 Electrical 9 Plumbing 10 Commissioning 17 Maximum Temperature Setting 18 Disabling the Temperature Override Button 20 Operation 21 Fault Diagnosis 22 Fault D...

Страница 4: ...MAKE SURE SUPPLEMENTARY BONDING COMPLIES WITH THE REQUIREMENTS FOR ELECTRICAL INSTALLATIONS In accordance with the current edition of The Plugs and Sockets etc Safety Regulations in force at the time...

Страница 5: ...ces speciied by the local electricity supply company in force at the time of installation The installation should be carried out by an electrician or contractor who is registered with or is a member o...

Страница 6: ...trol Knob 1 x Temperature Indicator Trim 3 x Rubber Feet 1 x Push Fit Release Tool 3 x Rubber Wall Plugs 3 x Fixing Screws Tick the appropriate boxes to familiarise yourself with the part names and to...

Страница 7: ...6 DIMENSIONS All dimensions are nominal and in millimetres 310 66 28 210 28 20 20 130 80 88...

Страница 8: ...in 1 C of selected temperature with a 10 C change in the hot or cold water supply If the cold supply fails the thermostatic mixer will shut down low of water to seepage levels in approximately 2 secon...

Страница 9: ...8 Gravity Fed system The shower MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressure INSTALLATION REQUIREMENTS 10 m Maximum 80 mm Minimum 30 60...

Страница 10: ...hower unit is designed for surface mounting only and must not be recessed into any wall or cavity or tiled up to as this prevents air circulating to the rear of the unit Electrical 1 The shower unit m...

Страница 11: ...nsfer may damage plastic components 5 Do not use jointing compounds on the shower unit joints they may cause damage to the mechanism inside 6 Do not insert ingers into the push it connections 7 The su...

Страница 12: ...ition on the slide bar the handset does not fall below the minimum clearance gap between the bath or shower tray spillover level of 25 mm 2 Hot and cold inlet supply connections are Hot Left Cold Righ...

Страница 13: ...trunking not supplied Allow suficient cable to connect to the terminal block approximately 275 mm Strip back approximately 30 mm of outer cable insulation 5 Loosen the three cover securing screws and...

Страница 14: ...structures 9 Use the push it release tool to push the grey collars into the manifold to release the shower unit from the supply pipes Warning Make sure there are no buried cables or pipes near the ix...

Страница 15: ...e of the unit 13 Fit the blanking plates to the unit case in the following manner For Top Inlet Pipework For Rear Inlet Pipework For Bottom Inlet Pipework Rubber Feet Fit the full blanking plates to t...

Страница 16: ...pplied or alternative ixings depending on the wall structure Do not over tighten Make sure that the electrical supply cable is correctly seated in the channel in the back of the case 17 Connect the li...

Страница 17: ...21 Insert the temperature indicator trim and the inner temperature control knob 22 The power thermostatic shower will now require commissioning refer to COMMISSIONING 23 Install the shower ittings ref...

Страница 18: ...eaks 3 Switch on the electrical supply 4 Turn the outer flow control anticlockwise to full low 5 Rotate the inner temperature control anticlockwise to check the hot supply and clockwise to check the c...

Страница 19: ...ture stop Do not depress the override button 3 Check the shower temperature 4 If the maximum temperature requires adjustment then remove the outer low control and the inner temperature control knobs S...

Страница 20: ...h the retaining screw 8 Insert the outer low control knob in the maximum low position 9 Insert the temperature indicator trim and the inner temperature control knob Caution If resistance is felt when...

Страница 21: ...h it release tool under the outer low control knob and lever the control knob assembly off the shower unit 3 Unclip the concealed end of the override button from the temperature indicator trim and car...

Страница 22: ...for warmer water and clockwise for cooler water the numbers indicate the relative temperature 1 cold 4 tepid 7 Hot Warning Operation of the override button will allow a shower temperature above the p...

Страница 23: ...ater temperatures do not exceed 65 C Reset maximum temperature refer to COMMISSIONING Blend temperature unstable Spray plate blocked Inlet ilters blocked Isolating valve partially closed Plumbing syst...

Страница 24: ...is too high up the pipe Refer to the plumbing system diagram in the INSTALLATION REQUIREMENTS for the correct connection method Note the 1 metre hot takeoff dimension Consider increasing the cold fee...

Страница 25: ...ssembly The pump does not operate Electrical supply failure PCB failure Potentiometer failure Motor overheated thermal switch operated Check the power supply Renew the PCB Renew the harness assembly I...

Страница 26: ...ore replacing any parts make sure that the underlying cause of the malfunction has been resolved Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for c...

Страница 27: ...mponents identiied C 453 13 Solenoid Valve Assembly components identiied D 453 14 Filter Cap Assembly 453 15 Seal Pack components identiied E 453 22 Stud Wall Fixing Kit Push it Release Tool 3 x Fixin...

Страница 28: ...27 147 67 453 01 453 14 A B H A D E D E B D 1532 332 453 28 A F A E G E B E F E C C G H G H G 453 08 1532 365...

Страница 29: ...ogramme calls may be recorded or monitored Our Customer Services Team is comprehensively trained to provide every assistance you may need help and advice spare parts or a service visit Spare Parts We...

Отзывы: