43
42
You can then use the Mira App to control your Digital Mixing Valve remotely via the
water droplet symbol and/or adjust your setting using the gear symbol.
Warning! Never remotely operate or alter any of the Mira Mode Maxim shower
settings if it is already occupied and / or being used by another person. This
could result in flooding of the shower cubical or scalding of the user.
The Bluetooth
®
word mark and logos are registered trademarks owned by Bluetooth
SIG, Inc. and any use of such marks by Kohler Mira Ltd. is under license. Other
trademarks and trade names are those of their respective owners.
3
Read the section “Important Information” first. If any maintenance is required then it must
be carried out by a competent tradesperson. Before replacing any parts make sure that the
underlying cause of the malfunction has been resolved.
Warning! There are no user serviceable components beneath the cover of the appliance.
Only a competent tradesperson should remove the cover.
Fault Diagnosis
Symptoms
Probable Cause
Possible Remedy
Loss of control via the User
Interface or On/Off Remote Button.
Shower turning On/Off or altering
blend temperature unexpectedly.
Another user is controlling the
shower remotely with the mobile
phone APP.
Not product fault. Ensure no one
else uses the mobile phone APP
whilst you are showering.
No water flow / will not turn on.
HP/Combi valve fitted to a Pumped
Gravity water system.
HP/Combi valves are not suitable
for Pumped Gravity water systems.
Refer to ‘Typical Installations’.
No power to Digital Mixing Valve.
Check electrical connection and
power supply.
Inlet water supply isolators not
fully turned on.
Check and remedy.
Inlet water supply failure.
Check and remedy.
Inlet filters or check valves
blocked.
Check and remedy, refer to
‘Maintenance’.
Outlet hose or handset blocked.
Check and remedy. Refer to
“Cleaning and User Maintenance”.
Digital Mixing Valve air locking.
Check for correct installation
practices, repeat commissioning
procedure and rearrange pipework
to avoid airlock forming, refer to
‘Typical Suitable Installations’.
Digital Mixing Valve box failure.
Contact Customer Services.
Low flow.
Inlet water supply isolators not fully
turned on.
Check and remedy.
Inlet filters or check valves
blocked.
Check and remedy, refer to
‘Maintenance’.
Outlet hose or handset blocked.
Check and remedy. Refer to
“Cleaning and User Maintenance”.
Inlet water pressures too low.
Check maintained water pressure
is within recommended range,
refer to ‘Specifications’.
Digital Mixing Valve air locking.
Check for correct installation
practices, repeat commissioning
procedure and rearrange pipework
to avoid airlock forming, refer to
‘Typical Suitable Installations’.
Digital Mixing Valve box installed
above cold water storage cistern
(Pumped valve only).
No product fault. Appliance
not suitable for negative head
installation, refer to ‘Installation’.
Settings
Maximum Temperature
Shower Duration
Name Bathroom
Standby Lighting
Connected Devices
Add/Remove Product
Technical Information
Factory Reset
Example Main Control Menu
(varies by product)
Example Settings Menu
(varies by product)