Decide on a suitable location for the ON/OFF button. Mark the centre position and 

draw a vertical line using a spirit level to assist in the alignment of the ON/OFF button. 

Using a suitable hole saw, drill a 29-30mm diameter hole to a minimum depth of 50mm.

Note: The ON/OFF button must be installed on a flat and even wall surface 

avoiding any grout lines.

Connect the cable to the back of the On/Off Remote Button and push the rubber 

grommet into place.

The alignment of the On/Off Remote Button cannot be adjusted when it is fitted.
Make sure to test fitment before removing the tape. This will ensure that there is no 

clearance issue.

Installation: On/Off Remote Button

1

3

Route the cable from the digital valve through the hole in the wall.

Note: Make sure that you use appropriate cable conduit / trunking to facilitate 

maintenance.

Using the cleaning wipe (supplied) clean the surface around the mounting hole.

Note: Do not remove the line at this stage.

2

Carefully remove the paper from the adhesive back.
Carefully, visually align the symbol to the vertical line on the wall. Locate into the hole 

in the wall and push firmly. Clean off the vertical line once the On/Off Remote Button 

is correctly installed. If required, the On/Off Remote Button can be removed from the 

backplate by rotating anticlockwise.

4

29 - 30mm

 

 

 

 

Содержание Mode Maxim

Страница 1: ...rantee on any replacement parts or product ends at the original expiry date For shower fittings or consumable items we reserve the right to supply replacement parts only What is Not Covered Call out c...

Страница 2: ...on videos datasheets or spares information please visit the Mira Showers website Contents Important Safety Information 4 Guarantee 6 Recommended Usage 6 Pack Contents 7 Specifications 12 General insta...

Страница 3: ...DO NOT perform any unspecified modifications drill or cut holes in the product other than instructed by this guide When servicing only use genuine Mira Showers replacement parts 11 DO NOT operate the...

Страница 4: ...fittings must provide a minimum air gap of 25mm between the handshower and the spill over level of any bath shower tray or basin There must be a minimum distance of 30mm between the handshower and th...

Страница 5: ...m Screws 2 x 70 mm Screws 1 x Slide Bar Assembly 1 x Handset 1 x Component Pack 1 x Hex Key 2 x Hex Screws 2 x Brackets 1 x Hose 2 x Rubber Washers 3 x Wall Plugs 3 x Fixings Screws 1 x Component Pack...

Страница 6: ...Assembly 1 x Rain Core 1 x Core Removal Tool 1 x Chrome Supply Tube 1 x Ceiling Mount Plate Assembly 1 x Shower Arm 1 x Concealing Shroud 1 x Deluge Head 2 x Wall Plugs 2 x Fixing Screws 1 x Cable 1 x...

Страница 7: ...conditions Ambient Temperature 1 C 40 C Maximum Relative Humidity 95 non condensing Flow Rates Nominal Flow Rate Valve capable of up to 16 l min 1 bar Electrical Supply Voltage 230V ac 50 Hz Maximum L...

Страница 8: ...ose to the Digital Mixing Valve for ease of maintenance Caution Risk of product and property damage The Digital Mixing Valve must be installed in a dry ventilated area where it will not freeze The sho...

Страница 9: ...tem Boiler Rating 24 kW 80 000 Btu h 30 kW 100 000 Btu h 36 kW 120 000 Btu h Flow Regulator 7 litres min 9 litres min Not required Colour White Green White Orange N A 1 Unscrew hot inlet plastic nuts...

Страница 10: ...where Bluetooth communication with the Digital Mixer Valve is poor e g mixer valve installed under metal bath in front of metal cistern on foil backed plasterboard Water supply pipes must be flushed p...

Страница 11: ...ion with the fixing screws supplied Caution Risk of product damage Make sure both hot and cold supply pipes are flushed thoroughly prior to connection to the Digital Mixing Valve Any product malfuncti...

Страница 12: ...he Controller in the backplate and press down on the bottom button as you install in position Installation Controller 1 3 4 5 For solid walls drill the fixing holes for the backplate with a 6mm drill...

Страница 13: ...itment before removing the tape This will ensure that there is no clearance issue Installation On Off Remote Button 1 3 Route the cable from the digital valve through the hole in the wall Note Make su...

Страница 14: ...are as follows Fix at convenient height for all the family Position the fittings so that water sprays down the centre of the bath or away from the opening of a shower cubicle Water should spray away...

Страница 15: ...assembly Note Do not fit the handshower until after pipework has been fully flushed through Refer to Commissioning b Fit the shower hose to the handset Make sure that you fit the shower hose and flow...

Страница 16: ...cutter to cut the pipe to the desired length Note Cut the brass pipe at least 75mm above the ceiling mount plate to allow room to fit the olive nut and elbow 4 Offer the chrome shroud to the brass pip...

Страница 17: ...ittings Suitable for solid dry lined stud partition shower cubicle or laminated panel walls Plan installation location of the handshower and deluge showerhead before installing fittings kit Note Make...

Страница 18: ...osition of the fixing hole in the top support 2 6 4 5 Drill the fixing holes fit the wall plugs and secure the backplate to the wall with two fixing screws 3 Drill the fixing hole for the top support...

Страница 19: ...e Head Fix at convenient height for all users Position so that water sprays down the centre of the bath or away from the opening of a shower cubicle Make sure that the water sprays away from the Contr...

Страница 20: ...Press the button to turn the shower on and reduce temperature to full cold For Low Pressure pumped version let shower run in order to prime the pump For long pipe runs allow 3 4 minutes for priming C...

Страница 21: ...p half for 10 Seconds approx until the Temperature Indicator light pulses on off Note After 5 seconds the lights will pulse to indicate pairing mode you need to continue to hold the button for the ent...

Страница 22: ...itable for Pumped Gravity water systems Refer to Typical Installations No power to Digital Mixing Valve Check electrical connection and power supply Inlet water supply isolators not fully turned on Ch...

Страница 23: ...alve only Refer to Use of Flow Regulators for correct operation Outlet pipe run is too long Ensure outlet pipe work is thermally lagged Symptoms Probable Cause Possible Remedy Showering temperature to...

Страница 24: ...s Mira Mode Showering App corrupted Delete the Mira Mode showering App reboot the mobile phone and re install the Mira Mode showering App No Lights on interface Not connected to valve Check all cables...

Страница 25: ...ccess to the checkvalve cartridges and filters Use a flat blade screwdriver to carefully lever the cartridges out Remove the filters and clean or renew Refit seals pipes and plastic nuts Plastic nuts...

Страница 26: ...50 Notes...

Отзывы: