17
25 mm minimum
Spill-over level
Hose Retaining
Ring
Temperature
Control Knob
Cover Retaining
Screw
Cover Retaining
Screws
Push-fit
Release
Tool
3. Shower Installation
The following installation procedure is based on a bottom entry pipework configuration
(rising hot and cold water supplies) and a top entry electrical supply configuration (via
miniature trunking from above). Using this procedure as a guide, adjust the steps for
alternative water supply or electrical supply configurations as appropriate.
3.1.
Decide on a suitable location for
the Mira Extreme
avoiding buried
cables and pipes
. Leave a
minimum distance of 200 mm
from the ceiling to
allow for the
fitting and removal of the cover.
Ensure that when the hose
retaining ring is placed on the
lowest position on the slide bar,
there is a
minimum distance of
25 mm between the handset
and the bath or shower tray
spillover
when the handset is
hanging down.
3.2.
Fit the three rubber feet into the
recesses in the case as shown.
The feet will reduce the noise
transmitted by the power shower
through the wall.
3.3.
Insert the end of the push-fit tool
under the temperature control
knob, inline with the temperature
override button, and lever off the
temperature knob.
3.4.
Unscrew the three retaining
screws sufficiently to remove the
shower cover.
Note!
The cover retaining screws
are captive and need not be
removed.
3.5.
Remove the cover electrical
connection from the PCB (as
described in detail in "
Configuring
Inlet Supplies
").
Rubber
Feet
Содержание Extreme Thermostatic
Страница 7: ...7 Dimensions Section 4 All dimensions are nominal and in millimetres 310 95 117 80 66 28 20 210...
Страница 42: ...Notes...